Operation

Electric shock hazard:
This tool is not insulated. When
using this unit near energized
electrical lines, use only certified
non-conductive hoses and proper
personal protective equipment.
Failure to observe this warning
could result in severe injury or death.
Skin injection hazard:
• Do not use hands to check for
leaks.
• Do not hold hose or couplers
while the hydraulic system is
pressurized.
• Depressurize the hydraulic system
before servicing.
Oil under pressure easily punctures
skin causing serious injury, gan-
grene or death. If you are injured by
escaping oil, seek medical attention
immediately.
Wear eye protection when operating
or servicing this tool.
Failure to wear eye protection could
result in serious eye injury from
flying debris or hydraulic oil.
Greenlee Tools, Inc.
Use hoses, fittings, and other components rated
for 700 bar (10,000 psi). An under-rated component
may fail under pressure.
Failure to observe this warning could result in severe
injury or death.
Valve and other components may be
hot during and after operation. Allow
to cool before handling, or handle
with heat-resistant gloves.
Failure to observe this warning
could result in severe injury.
Note: Maintain proper footing and balance while using
the tool. Do not over-reach. Unsuitable footing and
balance may not allow counteracting normal or unex-
pected movement of the tool.
1. Start the power source.
Note: Allow the power source to run for a few
minutes to warm the hydraulic fluid.
2. Position the tool in the appropriate location or
position.
3. To start the tool, press the lever to ADVANCE.
Notes:
• When the hydraulic pressure reaches 207 bar to
276 bar (3000 psi to 4000 psi), you may release
the lever and it will stay in the ADVANCE position.
The tool will continue to advance until the intensi-
fier reaches 700 bar (10,000 psi).
• You may stop the tool at any time by pressing the
lever to NEUTRAL.
4. To retract the tool, press the lever to RETRACT.
5. When the tool is not in use, stop the power source
to reduce heat and wear on tool components.