Device Operation - tiko Energy Solutions K-Box A6 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

K-Box A6 User's Manual
Step 9
Close the relay cover. Put back the protection covers for the phase and
neutral terminals (IMAGE 8). Ensure the orientation of the covers (IM-
AGE 9).
Step 10
Put back the cover panel of the home distribution box to cover the elec-
trical contacts. Be sure that no electrical contact can be touched.
Step 11
Power on the system by enabling power in the electrical panel.
Step 12
To finalize the installation, all tiko devices must be configured using the
installation app.

Device Operation

The operation of the K-Box is subject to the control of the full system and operated by
the Data Center through the Gateway (M-Box). No user interaction is required.
On the front, there are two buttons, offering the following functionalities:
"Service" – not used anymore (no function assigned)
"Heating Powered" or "Switch":
o
o
LED Explanation
On the front, there are two green LEDs indicating:
"Link" – on if connected via Gateway (M-Box) to backend
"Heating Powered" or "Switch" – relay status (on if closed)
tiko Energy Solutions AG
Danger! An external voltage source can be present on the
wires to be connected to the relay clamps!
An auxiliary source (e.g., ripple control, UPS, generator, PV,
emergency PSU) can supply voltage even if the all the main
counters are open/disconnected.
Before any handling verify that there is no voltage on any
wires you handle.
Single Press – change relay state. If the K-Box is connected to the
backend, the relay might switch back as it is overwritten by the
backend settings.
Long press (10 s) – reset device.