NOTE: Should nails continue to jam frequently in nosepiece, have tool serviced by an
authorized PORTER-CABLE service center.

COLD WEATHER OPERATION

When operating tools at temperatures below freezing:
1.
Make sure compressor tanks have been properly drained prior to use.
2.
Keep tool as warm as possible prior to use.
3.
Make certain all fasteners have been removed from magazine.
4.
Lower air pressure to 80 psi or less.
5.
Reconnect air and load nails into magazine.
6.
Turn pressure up to operating level (not to exceed 100 psi) and use tool as normal.
7.
Always drain the compressor tanks at least once a day.
HOT WEATHER OPERATION
Tool should operate normally. However, keep tool out of direct sunlight as excessive
heat can deteriorate bumpers, O-rings and other rubber parts resulting in increased
maintenance.
BELT HOOK (FIG. 1, 8)
The integrated belt hook (J) can be assembled to either side of the tool to accommodate
left- or right- handed users. If the hook is not desired at all, it can be removed from the
tool.
To remove or assemble belt hook
1.
Make sure safety trigger (B) has the trigger (A) locked off.
2.
Disconnect the tool from air supply.
3.
Using the appropriate hex wrench, remove the belt hook (J).
4.
Assemble belt hook to other side of nailer in hole (P) and tighten screw securely.
Fig. 8