10 www.electrolux.com
• Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect the blue neu-
tral cable to the terminal with a letter "N"
on it. Connect the brown (or black) phase
cable to the terminal which has a letter
"L". Keep the phase cable connected at
all times.
8.3 Connection cable
Use only connection cable of type
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
8.4 Building In
min.
55 mm
480 mm
10 mm
A)
supplied seal
min.
min.
650 mm
100 mm
30 mm
560 mm
3 mm
11 mm
A)
supplied seal
B)
supplied brackets
8.5 Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance intervention
is necessary.
A
A)
Removable panel
11 mm
B)
Space for connections
B
CAUTION!
Install the appliance only on a
worktop with flat surface.
30 mm
min 20 mm
A
(max 150 mm)
60 mm
B
A