Maintenance Schedule - Makita MAC3001 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATING YOUR AIR COMPRESSOR
ELECTRIC DRIVE
5) Stop/Start pressure switch control
a) Turn pressure switch "Off/Auto" switch to "Auto". Electric motor
should now start and fill air receiver(s) with compressed air until
cut-out pressure is reached. Compressor should stop and remain
stopped until air receiver pressure reaches the cut-in pressure.
The unit will continue to cycle in this automatic operation until the
pressure switch is turned to the "Off" position and/or electric power
supply is disconnected).
DAILY OR BEFORE EACH USE
¾ Check oil level
¾ Drain condensation from air receiver(s)
¾ Check for any unusual noise or vibration
¾ Be sure all nuts and bolts are tight
WEEKLY
¾ Turn off power. Clean dust and foreign matter from cylinder heads,
motor, fan blades, intercooler and air receiver(s)
¾ Clean air filter by opening air filter, removing filter element and cleaning
it thoroughly with soapy water. Rinse thoroughly and allow to dry
completely before assembly.
¾ Worn filters should be replaced
¾ Check V-belts for wear
10

MAINTENANCE SCHEDULE

EXTRA CARE SHOULD BE TAKEN TO AVOID
PERSONAL INJURIES WITH AUTOMATICALLY
CONTROLLED COMPRESSORS