the mode of dehumidification for the first
time if the measured value is larger than the
sum value of set humidity value and
dehumification return difference, the
equipment will start to dehumidify after the
set delay time.
The equipment will dehumidify immediately if
the interval time of two adjacent
dehumidification is longer than the delay time.
The equipment will dehumidify after delay
time if the interval time of two adjacent
dehumidification is shorter than the delay
time.
The delay time start timing when last
dehumidification is done.
Note: There is no need to judge the delay time
when power on or exiting the setting state.
6.4 Humidity Calibration (CA)
If the measured humidity differs from the
standard humidity, you can calibrate the
device by adding or reducing the correction
value to align the measured humidity to the
standard humidity. The calibrated
humidity = the measured humidity value + the
calibration value.