3
0
4
1
0
5
1
0
6
1
0
6
2
0
6
3
0
ACCES CONTROL PROGRAMMING
It defines the activation code of the panic function.
Proceed as detailed on 11 field.
It defines the contact type of the relay n.1.
Select 0 for normally open operation.
Select 1 for normally closed operation.
In case of power supply failure and n/c operation,
the relay will switch to n/o status.
1
or
Factory default: 0 (n/o).
It defines the activation type of the relay n.1.
Select 0 for single shoot operation.
Select 1 for stable operation.
Factory default: 0 (single shoot).
1
or
It defines the activation time of the relay n.1.
Only valid when programmed as single shoot.
Select a value from 01 to 20 (seconds).
Factory default: 03 seconds.
5
It defines the activation time of the relay n.2.
This relay only operates as single shoot.
Select a value from 01 to 20 (seconds).
Factory default: 03 seconds.
5
It defines the activation time of the panic output.
Select a value from 01 to 20 (seconds).
Factory default: 03 seconds.
5
F
unction fields and values.