GE VE1012PI Manuel D'installation page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8
1
J3 J4
CP
EN: Installation Sheet
Introduction
The VE1012PI is a PIR motion sensor with pet friendly optics.
Installation guidelines
The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability such as
(see Figure 1):
Direct sunlight on the detector
Strong draughts onto the detector
Heat sources within the detector field of view
Animals above 35 cm (1 ft.) within the detector field of
view (see Figure 7)
Obscuring the detector field of view with large objects,
such as furniture
Installing the detector
1.
Lift off the custom insert and remove the screw
(see Figure 2, item 1).
2.
Using a screwdriver, carefully prise open the detector (see
Figure 2, items 2 and 3).
3.
Fix the base to the wall between 2.3 m and 3.0 m (7.6 and
9.8 ft.) from the floor. For flat mounting use a minimum of
two screws (DIN 7998) in positions A. For corner-mounting
use screws in positions B or C (Figure 3). To install a pry-
off tamper, use position A or B.
4.
Wire the detector (see Figures 3 and 8).
5.
Select the desired jumper and DIP switch settings (see
Figure 6). See "Jumper settings" below for more
information.
6.
Remove the blinders and add the stickers, if required (see
Figure 5 for an example).
7.
For ceiling-mount applications that require a 90° coverage,
use the SB01 swivel-mount bracket.
8.
Close the cover.
P/N 146413999-2 • REV 1.0 • ISS 20JUL10
2
J3 J4
CP
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Short
0
9.
Insert the screw and place the custom insert.
For EN 50131 Grade 3 installations, do not use mounting
position C.
Figure 8 legend
Item
Description
1.
Standard connection (factory default)
2.
Dual loop connection
CP
Control panel
WT
Walk test
Jumper settings
See Figure 6 for the jumper locations in the detector.
J1: Not used
J2: PIR enabling the LED
On: Enables the detector LED at all times (default).
Off: Puts the LED under control of the control panel and
disables the detector LED at all times (no memory feature).
J3 and J4: Dual loop setting
This sets the alarm and tamper relays. It allows you to connect
the detector to any control panel. Use jumpers 3 and 4. See
Figure 8.
LED indication
PIR
Red LED
Start up
Low voltage
PIR intruder
alarm
Continuously on
J3 J4
J3 J4
J3 J4
CP
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Short
0
Alarm relay
To reset
Closed
Automatically after 25 s
Open (Alarm)
Apply correct voltage
Open (Alarm)
Automatically after 3 s
Normal blinking (1 Hz)
3 / 12

Publicité

Table des Matières
loading

Table des Matières