Remaining Risks; Technical Data - Meec tools 009874 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 60

Remaining risks

The use of the appliance can involve the
following risks.
Vibration injuries (if the appliance is
used for long periods, or is not
handled and maintained correctly).
Personal injury and/or material
damage as a result of defective
accessories, or kickback resulting
from concealed objects.
Spray mist
Spray mist can form during high-pressure
washing. Avoid inhaling spray mist, it can
be harmful to health.
SYMBOLS
The machine is not suitable
for connection to the drinking
water supply unless it is
provided with a check valve.
Keep at a safe distance of at
least 15 metres.
Double insulation.
Safety class II.
Sound power level.
92
Read the instructions.
Approved in accordance with
the relevant directives.
Recycle discarded high-pressure
washer in accordance with local
regulations.

TECHNICAL DATA

Rated voltage
Output
Safety class
Protection rating
Automatic starting/stopping
Rated pressure
Max pressure
Flow
Max flow
Max inlet pressure
Hose length
Cord length
Size
Weight
Sound pressure level, LpA 76,3 dB(A), K = 3 dB
Sound power level*, LwA 89,5 dB(A), K = 3 dB
Sound power level**, LwA
Vibration
* Measured, ** Guaranteed
Always wear ear protection.
The declared values for vibration and noise,
which have been measured according to a
standardised test method, can be used to
compare different tools with each other and
for a preliminary assessment of exposure.
The measurement values have been
determined in accordance with EN 62335-2-79.
WARNING!
The actual vibration and noise level when
using tools may differ from the specified
maximum value, depending on how the
tool is used and the material. It is therefore
necessary to determine which safety
precautions are required to protect the user,
based on an estimate of exposure in actual
operating conditions (taking into account all
stages of the work cycle, e.g. the time when
the tool is switched off and when it is idling,
in addition to the start-up time).
230 V ~ 50 Hz
1500 W
II
IPX5
Yes
90 bar
125 bar
5,1 l/min, 306 l/h
6,8 l/min, 408 l/h
7 bar/0.7 MPa
5 m
5 m
60 x 30 x 25 cm
5,5 kg
92 dB(A), K = 3 dB
2.1 m/s², K = 1.5 m/s²
EN
37

Publicité

Table des Matières
loading