Fireplace Installation
Figure 8
240V Installations
CAUTION: Use the appropriate
wire to meet local and national
electrical codes for rated power
consumption.
To 240V direct wire:
1. Connect the L1 wire from the
unit to the L1 wire from the
power supply with a wire nut.
2. Connect the L2 wire from the
unit to the L2 wire from the
power supply with a wire nut.
3. Connect the N wire from the
unit to the neutral wire from the
power supply.
www.dimplex.com
4. Connect the G wire from the
unit to the ground wire from the
power supply with a wire nut
or attach the grounding wire
to the cover with the provided
grounding screw, by placing the
wire in-between screw and lock
washer and tighten (Figure 4).
5. Ensure that all wires are secure
and do not protrude past the
flame panel, so as not to be
visible after final assembly.
6. Continue to the final assembly
instructions.