Safety instructions

Using the device
The device, equipped with ultrasonic probes, enables the flow measurement of a fluid (gas or liquid) in a pipe.
It is important to set up the device correctly so that the measurement results are correct.
It is recommended that Ultraflux qualified personnel be called in to ensure this. This is strongly recommended
if your equipment is used to control a process, to intervene in a monitoring system, or in the case of other
applications where incorrect flow measurement would entail risks.
During normal operation, the unit must not be heated up in a way that could cause burns. No special
precautions need to be taken to allow it to cool down. If the temperature of the housing rises abnormally, it is
essential to switch off the device and send it to Ultraflux for expert evaluation. In the event of fire inside the
appliance, make sure to switch it off without opening or touching it, then call the competent services to secure
the place.
The unit must not be used beyond the possibilities and specifications published in this manual. It must be
stored in a dry place. It is advisable to wear PPE (Personal Protective Equipment) suitable for the environment
of the installation site.
The modification or disassembly of the unit must only be carried out by Ultraflux personnel. Ultraflux declines
all responsibility otherwise.
Connections as well as disconnections of the connectors must be carried out with the power off, insulated
equipment.
Ultraflux declines all responsibility for any incidents that may occur as a result of failure to observe these
instructions.
Equipments connected to the device
All equipment connected to the device must comply with the relevant safety standard and have SELV circuits.
(double insulation between primary and secondary)
Caution: The supply voltage of the measuring probes is high (may exceed 200V).
Maintenance work on the device
Interventions related to the maintenance of the device must only be carried out by Ultraflux personnel and
using only parts supplied by Ultraflux.
Temperature limits for Minisonic electronics
Use from -10°C to +60°C
Storage from -35°C to +60°C
4

General characteristics

Ultrasonic flow measurement by transit time measurement.
2 measuring cords (i.e. 4 probes)
Power supply: continuous 12-24Vdc or 110-220 Vac - Consumption: 7W typical, 15W peak.
Protection class: IP67 closed case
Dimensions / Weight
Width: 216mm / Height: 268mm / Depth (thickness): 90mm
Weight: 3.6 kg (with wall mounting plate)
Mechanics / Ergonomics
Aluminum housing
Wall mounting: special sheet metal rear panel + hole for locking screw accessible at the bottom of
the product
Monochrome graphic OLED display 128x64 pixels
Lexan keyboard with: 7 keys (same keys as the Minisonic II Portable)
Blue LED: ultrasonic operation
RGB LED for diagnostics (operation to be described according to the errors to be reported to the
user)
Cable glands
3x M20 type cable gland
Note: The M20 cable gland must be able to accommodate a reducer for the connection of two Pt100.
1x dedicated to the power supply
2x dedicated to In / Outputs and optional (module IN et module COM).
1x specifically assigned to the ethernet cable
2x M25 type double cable gland : dedicated to probes connection (1x double cable gland per cord)
Integrated wiring compartment / integrated connection
Basic functions
Power supply : 3,5mm 3 ways connector (base plate with pluggable screw terminal block)
USB : vertical USB type A socket
Ethernet : horizontal RJ45 socket
In/Output (4/20mA Hart compatible and 2 ways Digital output) :
Connectors with 3.5mm pitch (base plates with spring-cage (pluggable) terminal blocks)
Probe connection: on stepped connector (socket strips with pluggable screw terminal blocks)
Optional function / Modules
Module « IN » : 4/20mA Input or Double Pt100 (2 or 3 wires)
Module « COM » : RS485 or RS232 with automatic detection by the device
Connectors with 3.5mm pitch (base plates with spring-cage (pluggable) terminal blocks)
Electrical characteristics Inputs / Outputs
Digital output: Maximum output voltage of 500V between contact and its ground
Current 1 mA at a frequency of 10 kHz
Modules In:
Galvanic insulation between modules: 500V
5