Electrical Connections; Adjust Temperature With Water Running - Bradley Verge LVQ Serie Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
13

Electrical Connections

Each WashBar requires the same connections.
Connect DC power adapter male barrel
B
plug into master control female barrel
plug. Plug the DC power adapter into
the blower power cord.
Air/Water Sensor
Board Connector
(Red) - From
WashBar (Shorter
of 2 Sensor
Cables - Red)
Soap Sensor
Board Connector
- From WashBar
(Longer of 2
Sensor Cables)
LED Board
Connector - From
WashBar
(Gray Cable)
Make (3) connections from
A
the WashBar assembly as
shown (Air/Water Sensor,
Soap Sensor and LED)
14

Adjust Temperature with Water Running

WARNING This valve is NOT factory
preset. Upon installation,
the temperature of this
valve must be checked and
adjusted to ensure delivery
of a safe water temperature.
Water in excess of 110°F
(43°C) may cause scalding.
Bradley • 215-1842 Rev. E; ECO 18-08-023
DC Power
Adapter
This End to
Master Control
Box Female Barrel
Plug
USB for Software
Upgrades
Not Used
After all connections are made,
D
reference Master Control Box:
System Startup section later in
this manual.
Loosen Cap Screw about 1/4" (4-6
A
turns) and lift up cover (do not
remove).
Using cover, turn cartridge gently until
B
desired water temperature is reached.
Do not turn past stops as this may
damage unit. Push cover down and
tighten screw.
Dryer
Power Cord
Make barrel plug and
C
connector plug connections
Connector Plug
as shown.
to DC Valve Plug
2/4/2019
LVQD1
Female Barrel
Plug to Soap
Motor Control Box
Male Barrel Plug
Connector Plug to
Dryer Motor
(Gray Cable)
C
H
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Verge lvqd1

Table des Matières