Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

8- WIRING DIAGRAM

230V - 50 Hz
N
L1
OFF
PE
Green / Yellow
9- APRON MOUNTING (ALL MODELS)
8 mm
30 N.m
±3
10- COMPATIBLE TRANSMITTERS
The CENTRIS veoHz motor is compatible
only with SIMU veoHz transmitters.
Refer to the corresponding instruction manuals.
veoHz TSA 3B
veoHz command unit
11- LIMIT SWITCH SETTINGS
Perform all the programming with the transmitter that will control the closing.
The upper and lower stop points are mandatory (mounting with at least 2 M5 screws per stop point).
a-
b-
b-
EN
5/9
The installation of the power supply must comply with the standards in force in the country where it is
Blue
installed; the power line must be reserved exclusively for the motor and provided with adequate protection.
Brown
An all-pole disconnection device must be provided:
- Either via a power cable with a plug.
- Or by a switch providing a contact separation distance of at least 3 mm on each pole (see EN60335-1
2
1
standard).
- Make the connections when the equipment is not live.
- Do not connect the motor to a power source (mains) before completing the installation.
ON
OK
3 s.
no OK
The apron must be attached securely to the tube:
- If there is a curved plate, the links must be screwed to the
curved plate and/or the motor
- If there is no curved plate, one of the links, or the 1st blade,
must be screwed to the motor crown.
- Range of veoHz mobile transmitters: + or - 5 m in free field.
- max. 12 transmitters per motor in total.
Location of the PROG key
>>>
1- ENTER THE SETTINGS MODE
- Switch on the motor.
- Simultaneously press the keys ▲ and ▼ on a veoHz transmitter
—> The motor responds with a "short rotation".
This transmitter controls the motor with a press and hold mechanism
(by default).
2- SETTING THE ROTATION DIRECTION
Press the ▲ key on the transmitter:
a- If the shaft rotates in an upward direction, the direction is
correct and you can proceed to step 3.
b- If the shaft rotates in a downward direction, the direction is
incorrect and you must reverse the rotation direction by
pressing the
STOP key for at least 3 seconds
—> The motor confirms the setting by a "short rotation".
CHC M10 ZnBl
JZC10 ZnBl
2 max.
PROG