geminox QAA 73.110 Notice Technique page 40

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Level Line
Display
Konfig-
Function output3 clip-in function module
Ausgang3R
0: Default (function according to the hydraulic
1: Status output,
2: Alarm output
3: Operational signal
4: Switching off external transformer
5: Pump of the second heating circuit
6: DHW circulating pump
7: Actuating device with warm air curtain
C
621
8: Pump of the pressureless header
9: Basic function of controller clip-in module
10: Basic function K2,
11: Actuating device with full DHW charging
12: Actuating device when analog signal (at the
LPB : LPB Clip-in
605 LPBAdrGerNr LPB device number of LMU
C
C
606 LPBAdrSegNr LPB segment number of LMU
Level
Line
Display
C
700
Stoer1
C
701
StrPn1
C
702
StrDia1
C
728
StrAlba1
C
703
Stoer2
C
704
StrPn2
C
705
StrDia2
C
729
StrAlba2
C
706
Stoer3
C
707
StrPn3
C
708
StrDia3
C
730
StrAlba3
C
709
Stoer4
C
710
StrPn4
C
711
StrDia4
C
731
StrAlba4
C
712
Stoer5
C
713
StrPn5
C
714
StrDia5
C
732
StrAlba5
C
715
Stoer-akt
C
716
StrPn-akt
C
717
StrDia-akt
C
733
StrAlba_akt
C
724
MmiStatus
C
725
SwVersion-LMU
C
755
IonStrom
Function
diagram)
activated
activated, in connection with stratification
storage tanks,
clip-in function module) has exceeded the
threshold
1st past value of lockout code counter
1st past value of lockout phase
1st past value of internal diagnostic code
1st past value of ALBATROS error code
2nd past value of lockout code counter
2nd past value of lockout phase
2nd past value of internal diagnostic code
2nd past value of ALBATROS error code
3rd past value of lockout code counter
3rd past value of lockout phase
3rd past value of internal diagnostic code
3rd past value of ALBATROS error code
4th past value of lockout code counter
4th past value of lockout phase
4th past value of internal diagnostic code
4th past value of ALBATROS error code
5th past value of lockout code counter
5th past value of lockout phase
5th past value of internal diagnostic code
5th past value of ALBATROS error code
Current value of lockout code counter
Current value of lockout phase
Current value internal diagnostic code
Current value of ALBATROS error code
Selection of summer / winter operating modes
SW version of LMU for presentation on the OT parameter setting level
Measured value of ionization current
Range
0...255
2
0...255
1
0...14
0
Function
- 20 -
PARAMETER LIST
Factory setting : boiler version
0.9-9
2-13/2-17
5-25
2
2
1
1
0
0
10-50
2
1
0
Unit
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0-255
-
µA

Publicité