1.2 - Overview of heating engineer parameters

Line
Service values
Current room temperature setpoint HC1
51
Nominal, reduced or frost protection setpoint
Current room temperature setpoint HC2
52*
Nominal, reduced or frost protection setpoint
Outside temperature attenuated
53*
pressing both buttons -/+ for 3 s)
54*
Outside temperature composite
55*
Actual value 2 of d.h.w. temperature
56*
D.h.w. flow rate
57*
Actual boiler return temperature
58*
Actual value of the flue gas temperature
59*
Actual temperature of solar collector
61*
Actual temperature of solar storage tank
62
OpenTherm mode
63
Current flow temperature setpoint HC1
64*
Current flow temperature setpoint HC2
Space heating (HC1 et HC2)
Heating curve slope HC1
70
- - . - = HC 1 inactive
71
Minimum limitation of flow temperature HC 1 (TV1min)
72
Maximum limitation of flow temperature HC 1 (TV1max) TV1min ... TKmax
73
Parallel displacement of heating curve HC 1
74*
Type of building construction
Room influence
75*
Switching differential of room temperature (switch-off
76
point) - - . - = inactive
Adaption of the heating curve
77
78
Optimum start control maximum forward shift
79
Optimum stop control maximum forward shift
Heating curve slope HC 2
80*
- - . - = HC 2 inactive
81*
Minimum limitation of flow temperature HC 2 (TV2min)
82*
Maximum limitation of flow temperature HC 2 (TV2max) TV2min ... TKmax
83*
Parallel displacement of heating curve HC2
Domestic hot water
90*
Reduced setpoint of d.h.w. temperature (TBWR)
Release of d.h.w. heating
91
92*
Legionella function
Operating mode of d.h.w. heating
93*
Function
(is set to actual value by
- 14 -
Range/display
Unit
°C
4 ... 35.0
°C
4 ... 35.0
°C
-50 ... +50
°C
-50 ... +50
°C
0 ... 127
l/min
0 ... 16
°C
-40 ... 127
°C
-40 ... 500
°C
-40 ... 250
°C
-40 ... 127
-
Lite, Plus
°C
0...100
°C
0...100
-
2.5 ... 40.0
°C
8 ... TV1max
°C
K
-4.5 ... +4.5
-
Heavy, light
-
None, on HC 1,
on HC 2,
on HC1+ HC 2
K
0.5 ... 4.0
-
inactive,
active
min
0 ... 360
min
0 ... 360
-
2.5 ... 40.0
°C
8 ... TV2max
°C
K
-4.5 ... +4.5
°C
8 ... TBWw
-
24h/day,
1)
TSP
HC -1h,
TSP HC, TSP D.H.W.
-
Off, on
-
Without Eco,
with Eco
PARAMETER LIST
Factory
Resolution
setting
0.5
-
0.5
-
0.5
-
0.5
-
1
-
0.5
-
1
-
1
-
1
-
1
-
-
-
1
-
1
-
0,5
15.0
1
8
1
80
0.5
0.0
-
light
-
on HC1
0.5
0.5
-
inactive
10
100
10
30
0.5
8.0
1
8
1
50
0.5
0.0
1
40
-
24 h /day
-
on
-
with Eco