Main Control Installation - Airia LIFEBREATH PURE PERFORMANCE ERV Serie Guide D'installation

Table des Matières

Publicité

Main Control Installation

The Lifebreath Digital Control 99-DXPL02 is to be surface mounted onto a wall and the Lifebreath
Ventilation Control 99-BC04 may either be installed onto a flush mounted electrical switch box or
surface mounted onto a wall. Only one master control should be installed to a ventilation system (the
face plate on this illustration may not be exactly the same as yours).
Attention
Pay special attention not to damage the contact pins when removing and detaching the face plate (Figures B and C).
1.
For DXPL02 control, remove the operating
instructions card from the top of the control
(Figure A).
2.
Separate the face plate from the back plate by
firmly pulling apart (Figures B or C). Be careful
not to damage face plate contact pins.
3.
For DXPL02 control, place the back plate of
the control in the desired location on the wall
and pencil mark the wall with the right and left
screw holes (Figure D).
4.
For BC04 control, place the screws and
anchors. back plate of the control in the
desired location on the wall and pencil mark
the top and bottom screw holes.
(Figure E or F).
5.
For mounting the control without a Decora
plate, break off top and bottom tabs and refer
to Figure F for mounting. Remove the back
plate from the wall and mark the center hole
for the wires in the middle of the screw holes.
Refer to Figure D, E or F for dimensions.
6.
Drill (two) 1/8 in holes for the screws and wall
anchors (Figure D, E or F). For DXPL02 control,
a 1 in hole in the center (Figure D). For
drill
BC04 control, cut in a 3/4 in by 1 in oval hole
in the wall (Figure E or F).
7.
Pull 3 wire 20 gauge (min.) 100 ft length
(max.), through the opening in the wall.
8.
Connect red, green, and yellow to the wiring
terminals located on the back plate (Figure D, E
or F).
9.
Attach the back plate to the wall using two
supplied screws and anchors.
10.
Attach the face plate to the back plate (Figure B
or C). Note: Be careful to correctly align the
face plate to avoid damaging the face plate
contact pins.
11.
For DXPL02 control, insert the operating
instructions card into the control (Figure A).
12.
Connect the 3 wire 20 gauge (min.) 100 ft length (max.) to the terminal block located on ventilator (Red #3, Yellow #4
and Green #5).
Operating
Instruction
Card
Figure A
Figure C
Back
Plate
Face
Plate
Keep top / bottom
vent openings clear
1/8 in hole for
screw and
anchor
1 in x 3/4 in
0.75"
oval hole
for wire
opening
1"
Wiring
Terminals
1/8 in hole
for screw and
anchor
Figure E
Face
Plate
Keep top / bottom
vent openings clear
Figure B
(Two) 1/8 in holes for screws
and anchors
1.5"
1 in hole for
wire opening.
Figure D
Alternate Wall Mount
1/8 in hole for
screw and
anchor
1.625"
1 in x 3/4 in
oval hole
for wire
opening
1"
1.625"
Wiring
Terminals
Break off tab
Back
Plate
1.5"
Wiring
Terminals
Break off tab
Wire hole
centered
0.75"
between
screw
holes
1/8 in
hole for
screw and
anchor
Figure F
14