fadini Elpro 12 EVO Mode D'emploi page 14

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Elpro 12 EVO
GB
The following setting is required when Elpro 12 EVO is to be used in compatibility with Elpro 12 PLUS for NYOTA 115 old series and
therefore without encoder, electronic brake, slowdow and reversing on obstacle detection:
!
- set the electronic brake trimmer to the lowest
- set dip-switch 9 to ON
- set the torque trimmer to the highest as the mechanical clutch will be used.
SELECTION OF NYOTA 115 EVO EITHER 1,0 HP OR 0,5 HP
!
It is fundamental that the required model of Nyota 115 EVO be properly selected by dip-switch 11:
FUNCTIONING ON SLIDING GATES
Description
AUTOMATIC / SEMIAUTOMATIC:
Automatic operation: on pulsing an open command, the gate opens, stays open untill dwell time expires
as set by the dwell trimmer, then closes automatically.
Semiautomatic operation: on pulsing an open command, the gate opens and stops in open position.
A close pulse is needed for the gate to close.
RICLOSING ON PHOTOCELL ENGAGEMENT: in opening and dwell phases
(DIP-SWITCH N° 3=ON)
This function allows the gate to auto close after 3 s the photocell beam has been crossed.
DEADMAN CONTROL (hold-on-switched):
Open and close commands are performed "by holding a switch on" (no relay self-holding is involved)
therefore a phisical attendance is required to keep the gate running until either the button or key are
released.
PARTY FUNCTION
OPENING BY EXTERNAL TIME CLOCK:
Connect the NO contact of the time clock to terminals 4
OPEN and 3 COMMON, set the board to auto closing by
Dip-Switch 3=ON.
How it works: set the clock to the required opening time. On
the pre-set time the gate is opened and held open (the
flasher goes off ), and no more commands (even by radio) are
accepted until the clock pre-set time expires. On expiring,
and after the pre-set dwell time, auto closing is performed.
During dwell time with gate in open position on "time clock"
command, the pilot light gives out two short flashes
followed by a longer pause.
ELECTRONIC BRAKE SETTING
Description
- Trimmer set to 0 : electronic brake deactivated.
Important: set it always to this position for Nyota 115 old series fitted
!
with mechanical brake.
- Adjusting the electronic brake: it is possible to adjust brake intensity by the dedicated
Important: use the electronic brake function only with Nyota 115 EVO
!
ELECTRONIC CONTROL BOARD FOR NYOTA 115 EVO
DIP-SWITCH N° 11:
ON: Nyota 115 EVO 0,5 HP
OFF: Nyota 115 EVO 1,0 HP
11
3 4
trimmer
DIP-SWITCH N° 3:
3
DIP-SWITCH N° 8:
8
DIP-SWITCH N° 6:
6
DIP-SWITCH N° 3:
External time clock
3
IMPORTANT:
always and only with Dip N° 3=ON
NO
0
14
Dip-switch and LED indication
of the various functions
ON: automatic closing
OFF: semiautomatic
Dwell trimmer: dwell time is required to
be set when automatic mode is selected
2 s up to 128 s
ON: auto closing on photocell engagement
after 3 seconds
OFF: no auto closing on photocell
engagement
ON: deadman control activated
OFF: deadman control deactivated
ON: auto closing
Trimmer
Electronic brake trimmer:
set it to 0 for Nyota 115 with mechanical
brake
Electronic brake trimmer:
set it as required to control brake intensity
with Nyota 115 EVO