Cooke & Lewis CLMFBIa Mode D'emploi page 7

Masquer les pouces Voir aussi pour CLMFBIa:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
Installation
All installation must be carried out by a competent person or qualified electrician. Before connecting
the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate.
Direct Connection
This appliance must be connected directly to the mains using an omnipolar circuit breaker with a
minimum opening of 3 mm between contacts.
The installer must ensure that the correct electrical connection has been made and that it complies
with the wiring diagram.
The cable must not be bent or compressed.
Regularly check the power cord for damage.
WARNING: This is a Class I appliance and MUST be earthed.
This appliance is supplied with a 3 core mains cable coloured as follows:
Brown = L or Live
Blue = N or Neutral
Green and Yellow = E or Earth
EUR
N
L
N
(Blue)
L
(Brown)
(Green/Yellow)
The fuse must be rated at 16 Amps.
To avoid the risks that are always present when you use an electrical appliance it is important that
this appliance is installed correctly and that you read the safety instructions carefully to avoid misuse
and hazards. Please keep this instruction booklet for future reference and pass it on to any future
owners. After unpacking the appliance please check that it is not damaged. If in doubt, do not use the
appliance but contact Customer Services.
The manufacturer declines all liability for damage caused to persons and objects due to incorrect
or improper installation of the appliance. Any permanent electrical installation must comply with the
UK
N
L
7
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
FUSE ON
USE A 16AMP FUSE

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

ClmfmiaClmfsta366360242955536636024295623663602429548

Table des Matières