Operating Instructions and Replacement Parts List
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
The Wayne pumps are general use
centrifugal water pumps.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially
hazardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
potentially
hazardous situation which, if not avoided,
may result in minor or moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
General Safety
Information
1. Know the pump application,
limitations, and potential hazards.
Read these rules and the instructions
carefully. Failure to follow them could
cause serious bodily injury and/or
property damage.
Never run engine in an
enclosed area. Exhaust gases
contain deadly poisonous carbon
monoxide, which has no odor or taste.
Engine Driven
Semi-Trash
Pump
Do not use to pump flammable
or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Do not
use in flammable and/or explosive
atmospheres. Pump should only be used
with liquids compatible with pump
component materials. Failure to follow
this warning can result in personal injury
and/or property damage.
2. Observe all safety precautions for the
handling of the fuel.
Do not refuel a hot engine.
Fuel spilled on a hot engine
could result in a fire or explosion. Do not
refuel a running engine.
3. Pump should be located and should
rest on a level solid foundation. Do
not suspend pump by means of the
discharge pipe.
Be sure pump is on
secure footing so it
doesn't fall over.
4. Do not use torches or apply excessive
heat, fire or flames to this pump as an
explosion may result.
5. Before working on the unit, insulate
the wire from the spark plug,
disconnect the spark plug wire and
mount it on the grounding clip.
Complete pump
and piping system
MUST be protected against below
freezing temperature. Failure to do so
could cause serious damage and voids
the warranty.
6. Do not run pump dry. Water is
required to lubricate the shaft
seal.
7. Pumping chemicals or corrosive
liquids with this pump may shorten
1
GPH400 and GPH550
the life of the pump and may be
hazardous to the operator.
8. Personal Safety:
a. Wear safety glasses at all times
when working with pumps.
b. Keep work area clean, uncluttered
and properly lighted; replace all
unused tools and equipment.
c. Keep visitors at a safe distance from
the work area.
d. Make workshop child-proof with
padlocks, master switches, and by
removing starter keys.
9. Always use a suction strainer with this
pump to filter large material.
Installation
This pump is designed to be self-
priming when installed and operated as
specified below.
1. The pump should be placed as close
as possible to the liquid being
pumped. A pump with 20 foot
suction lift will not remove water as
quickly as a pump with 5 foot
suction lift (Figure 1).
20 Ft.
Suction Lift
5 Ft.
Suction
Lift
Figure 1
2. Suction hose and fitting must be
airtight.
320802-001 12/03

Publicité

loading

Sommaire des Matières pour Wayne GPH400

  • Page 1 Description hazardous to the operator. 8. Personal Safety: The Wayne pumps are general use Do not use to pump flammable centrifugal water pumps. or explosive fluids such as a. Wear safety glasses at all times gasoline, fuel oil, kerosene, etc.
  • Page 2 Operating Instructions and Replacement Parts List 9. Add water to the priming port on Do not use this pump for suction lifts Installation the pump (See Figure 3). Continue over twenty-five feet. (Continued) adding water until the water level is Maintenance approximately 3 inches from the An air leak in the...
  • Page 3 Operating Instructions and Replacement Parts List Performance Information Semi-Trash Pump Performance GAS PERFORMANCE Model Discharge Head 0’ 20’ 40’ 60’ 80’ GPH400 Gallons/Hour 6600 5700 5100 4500 3900 GPH550 Gallons/Hour 16800 14400 12000 9000 4620 FEET FRICTION LOSS IN 100 FEET OF PLASTIC PIPE...
  • Page 4 - Serial number (if any) 100 Production Drive - Part description and number as shown Harrison, OH 45030 400 PUMP 4HP HONDA OHV GPH400 3” HOSE KIT 62025-WYN1 550 PUMP 5.5 HP HONDA OHV GPH550 2” HOSE KIT 62005-WYN1 LAY FLAT DISCHARGE HOSE 2”...
  • Page 5 Operating Instructions and Replacement Parts Manual For Replacement Parts, call 1-800-237-0987 Please provide following information: Address parts correspondence to: - Model number Wayne Water Systems - Serial number (if any) 100 Production Drive - Part description and number as shown Harrison, OH 45030 11, 12 TX2) or (WKT2) is noted here.
  • Page 6 Limited Warranty For three years from date of purchase, Wayne Water Systems (”Wayne Water Systems“) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (”Product“) found upon examination by Wayne Water Systems to be defective in materials or workmanship.
  • Page 7 Conserver ces instructions comme référence. Pompe de résidus à moteur Pump Description Les pompes Wayne sont des pompes à 6. Ne faites pas tourner la pompe l’eau centrifuges d’utilisation générale. à sec. Il faut de l’eau pour Ne pas utiliser pour le pompage lubrifier le joint de l’arbre.
  • Page 8: Entretien

    Operating Instructions and Replacement Parts List 8. Remplissez le réservoir d’essence d’aspiration. Si le tuyau flexible Installation du moteur d’essence. Reportez- d’aspiration est utilisé au lieu d’un tuyau (Suite) vous au manuel de rigide, utiliser un tuyau renforcé de deux fonctionnement du moteur pour le pouces de diamètre intérieur.
  • Page 9 Instructions d’Utilisation et Manuel de Pièces de Rechange Information sur la performance Performance de la pompe à résidus PERFORMANCE DU GAZ Modèle Tête de décharge 0’ 20’ 40’ 60’ 80’ GPH400 Gallons/Heure 6600 5700 5100 4500 3900 GPH550 Gallons/Heure 16800 14400...
  • Page 10: Tuyau D'aspiration

    100 Production Drive - Description et numéro de la pièce Harrison, OH 45030 U.S.A. POMPE 400 HONDA 4 HP OHV GPH400 KIT DE TUYAU DE 3 PO 62025-WYN1 POMPE 550 HONDA 5.5 HP OHV GPH550 KIT DE TUYAU DE 2 PO 62005-WYN CRÉPINE D’ASPIRATION DE 2 PO...
  • Page 11 Pour pièces de rechange, composer 1-800-237-0987 S’il vous plaît fournir l’information suivante: Correspondance: - Numéro de modèle Wayne Home Equipment - Numéro de série (si applicable) 100 Production Drive - Description et numéro de la pièce Harrison, OH 45030 U.S.A.
  • Page 12: Garantie Limitée

    Garantie Limitée Pendant un an à compter de la date d’achat, Wayne Water Systems ("Wayne") va réparer ou remplacer, à sa discrétion, pour l’acheteur original toute pièce ou pièces du Kit D’Étang, de ces Pompes De Puisard ou Pompes À Eau ("Produit") déterminées défectueuses, par Wayne, soit pour les matériaux ou la fabrication.

Ce manuel est également adapté pour:

Gph550