Napoleon Haliburton GDS28-1PSB Manuel D'installation Et D'opération page 50

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

troubleshooting (electronic)
EN
symptom
P ilot w ill no t lig ht. M a kes
n o ise w ith no sp a rk at
p ilo t b u rn er .
Pilot sparks but will
not light.
Burner continues to
spark and pilot lights
but main burner
does not light.
Remote wall switch
is in "off" position;
burner comes on.
Remote and / or
receiver is not
functioning properly.
50
W415-2339 / D / 02.04.22
problem
Wiring: short, loose, or damaged
connections
(poor fl ame rectifi cation).
No signal from remote with no
pilot ignition.
Poor grounding.
Improper switch wiring.
Dirty, painted, or damaged pilot
and/or dirty sensor rod.
Gas supply.
Out of propane gas.
Pilot supply line may contain
air.
Incorrect wiring / grounding.
Receiver (if equipped).
Valve.
Short or loose connection in
sensor rod.
Dirty, painted, or damaged
pilot assembly components.
Wall switch mounted upside
down.
Remote wall switch and/or
wire is grounding.
Faulty wire
Remote controls lights but
no spark or fl ame. (Remote is
locked out).
R eceive r o r rem ote has lo w b attery.
Appliance functions but does not
respond to receiver / remote
Error with synchronizing.
R em o te to o fa r a w ay fro m re c e ive r.
Wire connector pins are bent.
Valve wiring is damaged.
test solution
-
V erify th e th erm o co up le/sen so r is clean and the w irin g is u n d a m ag ed .
-
V erify th e in terrup te r b lo ck is n o t d am ag ed o r to o tig h t. V erify
co n n ectio ns fro m p ilo t asse m b ly are tig h t; also verify th e co nn ectio n s
are n o t g ro un d ing o u t to any m e tal. (R e m em b er , th e fl am e carries th e
rectifi catio n curren t, no t the gas. If fl am e lifts from p ilo t h oo d , th e c ircu it
is b ro ken . A w ro n g o rifi ce o r to o hig h o f an in let p ressu re can cau se th e
p ilo t fl am e to lift)*. Th e sen so r ro d m ay need cle aning .
-
Reprogram receiver code.
-
Replace receiver.
-
Verify the valve / pilot assembly are properly grounded
-
Troubleshoot the system with the simplest on/off switch.
-
Clean sensor rod with a green Scotch-Brite™ pad to remove any
contamination that may have accumulated. Verify continuity with
multimeter with ohms set at the lowest range.
-
Verify that the incoming gas line ball valve is "open".
-
Verify that the inlet pressure reading is within acceptable
limits, inlet pressures must not exceed 13" W.C. (32.4mb).
-
Fill the tank.
-
Repeat ignition process several times or purge the pilot
supply line.
-
Ensure correct polarity of wiring of thermocouple (if
equipped).
-
Verify pilot assembly / valve are properly grounded.
-
Reset program: hold reset button on receiver and wait for 2
beeps. Release after second beep. Press small fl ame button
on remote within 20 seconds, you will hear an additional
beep (this signals a successful reset).
-
Replace receiver.
-
Check valve and replace if necessary (Do not to overtighten
thermocouple).
-
Verify all connections. Verify the connections from the pilot
assembly are tight. Also, verify these connections are not
grounding out to any metal.
-
Clean using a green Scotch-Brite™ pad to remove any
contamination that may have accumulated on the sensor
rod, pilot hood, ignitor, or fl ame sensor. Verify continuity with
multimeter with ohms set at the lowest range.
-
Reverse.
-
Replace.
-
Check for ground (short); repair ground or replace wire.
-
Replace.
-
Reset by turning power source off then on.
note:
If back up batteries are installed, they must also be removed to
re-program
-
Replace batteries.
-
Ensure appliance is being operated by the same device that turned it
on. Remote controls function if appliance was turned on by remote.
Receiver controls function if appliance was turned on by receiver.
-
Reset receiver and remote.
-
Refer to "wiring diagram" section.
-
Straighten pins.
-
Replace valve.

Publicité

Chapitres

Table des Matières
loading

Table des Matières