NATURAL GAS MODELS:
PROPANE GAS MODELS:
SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be
performed by a qualifi ed installer, service
agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
$10.00
GDS28-1NEA / GS28-1NEA
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
GDS28-1PEA / GS28-1PEA
Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com
INSTALLATION AND
ADD MANUAL TITLE
OPERATION MANUAL
Model GS28 is made up of Model GDS28 and
Natural Vent Adapter Kit GS-150KT
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
IF INSTALLATION + OPERATION, ADD SERIAL
CSA /
INTERTEK
BARCODE LABEL ON THE OWNER'S MANUAL"
LOGO
Product Name / Code
Haliburton™
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
FOR INDOOR USE ONLY
NUMBER LABEL HERE
IF SEPARATE MANUALS, ADD "PLACE
ENGLISH
FRENCH PG. 51
(GDS28-1 illustrated)
W415-4005 / A / 07.22.21

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Napoleon Haliburton GDS28-1NEA

  • Page 1 INTERTEK BARCODE LABEL ON THE OWNER’S MANUAL” LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com $10.00 W415-4005 / A / 07.22.21...
  • Page 2: Safety Information

    safety information WARNING DANGER • This appliance is hot when operated and can cause severe burns if contacted. • Any changes or alterations to this appliance or its controls can be dangerous and is prohibited. HOT GLASS WILL CAUSE • Do not operate appliance before reading and BURNS.
  • Page 3 patterns. RAAK HET GLAS NIET AAN TOT HET IS AFGEKOELD. DUTCH safety information LAAT KINDEREN NOOIT HET GLAS AANRAKEN. WARNING Dit apparaat is voorzien van een barrière die is ontworpen om het risico van brandwonden door het hete kijkglas te beperken. Deze barrière moet worden geïnstalleerd ter bescherming van kinderen •...
  • Page 4: Table Des Matières

    table of contents finishing general information safety screen installation and rates and efficiencies removal general instructions door closing and opening rating plate information log placement mobile home installation (model glowing embers GDS28) dimensions charcoal embers logo placement venting control access cover removal / typical vent installation installation special vent installations...
  • Page 5: General Information

    standard checklist Installer, please fill out the following information: Customer: _____________________________________________________________________ Address: _____________________________________________________________________ Date of Installation: _____________________________________________________________________ Location of Appliance: _____________________________________________________________________ Installer: _____________________________________________________________________ Dealer/Distributor Contact Number: _____________________________________________________________________ Serial #: _____________________________________________________________________ Model: Natural Gas: Propane: GDS28-1NEA GDS28-1PEA GS28-1NEA GS28-1PEA 1.0 general information When the appliance is installed at elevations above 4,500 ft (1372m), and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000 ft (305m).
  • Page 6: General Instructions

    general information general instructions WARNING • Always light the pilot, whether for the first time or if the gas supply has run out, with the glass door opened or removed. • Provide adequate clearance for servicing and operating the appliance. •...
  • Page 7: Rating Plate Information

    Recessed depth X” Profondeur d’encastré une face X” L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez au *** Mantel X” from appliance opening *** Tablette X” de l’ouverture de l’appareil manuel d’installation pour les spécifications d’évacuation. Il est nécessaire de bien réinstaller et *** Maximum horizontal extension: *** L’extension horizontale maximale: X”.
  • Page 8: Dimensions

    general information dimensions W415-4005 / A / 07.22.21...
  • Page 9: Venting

    2.0 venting WARNING • Risk of fi re. Maintain specifi ed air space clearances to vent pipe and appliance. • The vent system must be supported every 3’(0.9m) for both vertical and horizontal runs. Use support ring assembly W010- 0067 or equivalent non-combustible strapping to maintain the minimum clearance to combustibles for both vertical and horizontal runs.
  • Page 10: Typical Vent Installation

    The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged. Rigid and fl exible venting systems must not be combined. Different venting manufacturer components must not venting be combined.
  • Page 11: Special Vent Installations

    venting special vent installations 2.2.1 periscope termination Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum 12” (305mm) above grade. The maximum allowable vent length (including both rise and run) is 10’...
  • Page 12: Vent Terminal Clearances

    venting vent terminal clearances Covered balcony applications ††* = 3 feet ≤ 15 feet = 2 x ACTUAL (0.9m) (4.6m) note: INSTALLATIONS Wall terminals are for illustration purposes only. Size and shapes may vary. Wall terminal CANADA U.S.A. measurements taken from the exhaust outlet, not the mounting plate. 12”...
  • Page 13: Vent Flow Charts

    venting vent flow charts Top Exit Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than the to or greater than the than horizontal run than horizontal run horizontal run horizontal run Horizontal run +...
  • Page 14: Horizontal Termination

    venting horizontal termination ) < (V Simple venting confi guration (only one 90° elbow) See graph to determine the required vertical rise V for the required horizontal run H 40 (12.2) 39 (11.9) REQUIRED 30 (9.1) VERTICAL RISE IN FEET 20 (6.1) (METERS)V 40 (12.2)
  • Page 15 venting ) > (V Simple venting configuration (only one 90° elbow) See graph to determine the required vertical rise V the required horizontal run H 150 (3810) 147 (3733.8) REQUIRED VERTICAL RISE IN INCHES 100 (2540) (MILLIMETERS) V 57 (1447.8) 50 (1270) 29 (736.6) 20 (6.1)
  • Page 16: Top Exit Vertical Termination

    venting top exit vertical termination ) < (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H 40 (12.2) 30 (9.1) REQUIRED VERTICAL RISE IN FEET 20 (6.1) (METERS) V 10 (3.1) 3 (0.9) (1.5) (3.1)
  • Page 17 venting ) > (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H 20 (6.1) 19 (5.8) REQUIRED VERTICAL RISE IN FEET 10 (3.1) (METERS) V 3 (0.9) (7.6) (9.1) (1.5) (3.1) (4.6) (6.1)
  • Page 18: Vertical Through Existing Chimney

    venting vertical through existing chimney WARNING • Risk of fi re. • Co-axial to co-linear venting confi gurations must only be used in a non-combustible chimney or enclosure. Installation in a combustible enclosure could result in a fi re. This appliance is designed to be attached to a 3” (76.2mm) co-linear aluminum fl ex vent system running the full length of a masonry chimney.
  • Page 19: Installation

    3.0 installation WARNING • Ensure to unpack all loose materials from inside the fi rebox prior to connecting the gas and electrical supply • If your appliance is supplied with a remote, ensure the remote receiver is in the “OFF” position prior to connecting the gas and electrical supply to the appliance.
  • Page 20: Horizontal Installation

    installation 3.1.1 horizontal installation WARNING • The fi restop assembly must be installed with the vent shield to the top. • Terminals must not be recessed into a wall or siding more than the depth of the return fl ange of the mounting plate.
  • Page 21: Vertical Installation

    installation 3.1.2 vertical installation This application occurs when venting through a roof. Installation kits for various roof pitches are available from your authorized dealer / distributor. See the “accessories” section to order specifi c kits required. A. Determine the air terminal location, cut and frame a square opening, as illustrated, in the ceiling and the roof to provide the minimum 1"...
  • Page 22: Vertical Air Terminal Installation

    installation 3.1.4 vertical air terminal installation WARNING • Maintain a minimum 2” (51mm) space between the air inlet base and the storm collar. note: Fastening hardware provided with appropriate roof terminal and liner kits. Fasten the roof support to the roof using 6 screws. The roof support is optional.
  • Page 23: Appliance Vent Connection

    installation appliance vent connection REAR VENT TOP VENT - FLEX TOP VENT - RIGID/FLEX Attach the adjustable pipe to the last section of rigid pipe. Secure with #8 X 1/2” #8 X 1/2” screws and seal. #8 X 1/2” #8 X 1/2” Self Drilling Self Self Drilling...
  • Page 24: Installing Natural Vent

    installation 3.3.3 installing natural vent Follow the instructions of the natural vent manufacturer for chimney installation. Remove and discard the two combustion air cover plates B-VENT ADAPTER and gaskets located on the rear panel of the appliance. Replace the four screws per side to secure the rear panel to the appliance.
  • Page 25: Adding Vent Sections

    installation 3.3.5 adding vent sections Add chimney sections, according to the manufacturer’s installation instructions. If the chimney system passes through an attic space, a rafter radiation shield or attic insulation shield is required. The chimney must extend at least 3ft (0.9m) above its point of contact with the roof and at least 2ft (0.6m) higher than any wall, roof or building within 10ft (3.1m).
  • Page 26: Gas Installation

    4.0 gas installation WARNING • Risk of fi re, explosion, or asphyxiation. Ensure there are no ignition sources such as sparks or open fl ames. • Support gas control when attaching gas supply pipe to prevent damaging gas line. • Always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened or removed.
  • Page 27: Finishing

    5.0 finishing WARNING • Risk of fi re! • Never obstruct the front opening of the appliance. • The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite, etc., provided that these materials do not go below the specifi ed dimension, as illustrated. •...
  • Page 28: Door Closing And Opening

    finishing door closing and opening WARNING • Glass may be hot. Do not touch glass until cooled. • If equipped with door latches that are part of a safety system, they must be properly engaged. Do not operate the appliance with latches disengaged. •...
  • Page 29: Log Placement

    finishing log placement WARNING • Failure to position the logs in accordance with these diagrams or failure to use only logs specifi cally approved with this appliance may result in property damage or personal injury. • Logs must be placed in their exact location in the appliance. Do not modify the proper log positions, since appliance may not function properly and delayed ignition may occur.
  • Page 30: Glowing Embers

    finishing glowing embers WARNING • Completely blocking the burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. Tear the embers into pieces and loosely layer above the burner ports covering the burner area. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi bre hairs will glow.
  • Page 31: Operating Instructions

    6.0 operating instructions operating instructions operating/lighting instructions The on-off switch is located on the back of the appliance at the top left corner on models GDS28 and GS28. When lit for the first time, the appliance will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the "burn-in"...
  • Page 32: General Transmitter Layout

    operating instructions general transmitter layout note: The remote control is optional. The receiver switch must be in the REMOTE position for the transmitter to function. This remote system operates using radio frequency signals sent by the transmitter to the receiver. It is recommended that the distance between the transmitter and receiver never exceeds 20’...
  • Page 33: Battery Backup Installation

    operating instructions battery backup installation WARNING • Ensure the gas and electrical power to the appliance is turned off. • Appliance may be hot. Do not service until the appliance has cooled. note: In the event of a power failure, your appliance can be operated using the supplied battery back-up. Remove the safety barrier to easily access the control compartment.
  • Page 34: Wiring Diagram

    7.0 wiring diagram operating instructions WARNING • Do not wire 110 volts to the valve or wall switch. ILOT SSEMBLY W010-2863 (NG) GNITION W010-2900 (P) ODULE W190-0135 3/16” IRE TAGS ARE BRACKETED ROWN ROUND ÉLECTRODE ILOT VEILLEUSE 1/4” 3/8” - 1/2” (9,5mm - 12,7mm) LA SONDE ATTERY...
  • Page 35: Operation

    8.0 operation operation WARNING • If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. • If applicable, always light the pilot whether for the first time or if the gas supply has run out with the glass door opened or removed.
  • Page 36: Adjustment

    9.0 adjustment pilot burner adjustment Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. Check Pressure Readings: Inlet pressure can be checked by turning screw (A) counter- clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point.
  • Page 37: Venturi Adjustment

    venturi adjustment This appliance has an air shutter that has been factory set open according to the chart below: VENTURI Regardless of venturi orientation, closing the air shutter will cause a more BURNER yellow flame, but can lead to carbonization. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
  • Page 38: Maintenance

    10.0 maintenance WARNING • Turn off the gas and electrical power before servicing the appliance. • Appliance may be hot. Do not service until appliance has cooled. • Do not use abrasive cleaners on glass. • Do not paint the pilot assembly. This appliance and its venting system should be inspected before use and at least annually by a qualifi ed service person.
  • Page 39: Annual Maintenance

    maintenance 10.1 annual maintenance WARNING • Annual maintenance should be performed by a qualifi ed service technician • The fi rebox becomes very hot during operation. Let the appliance cool completely or wear heat resistant gloves before conducting service. • Never vacuum hot embers.
  • Page 40: Blower Replacement

    maintenance 10.3 blower replacement Blower replacement may be done through either the firebox or from the rear of the appliance. Using the rear panel is recommended. BLOWER INSTALLATION THROUGH THE REAR PANEL : FOR MODEL GDS28 white • Turn off the electrical power and the gas supply to the appliance. THERMAL •...
  • Page 41: Replacement Parts

    11.0 replacement parts WARNING • Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can be ordered through your Authorized dealer / distributor.
  • Page 42 replacement parts W415-4005 / A / 07.22.21...
  • Page 43 replacement parts W415-4005 / A / 07.22.21...
  • Page 44: Accessories

    12.0 accessories accessories W415-4005 / A / 07.22.21...
  • Page 45: Troubleshooting

    troubleshooting (electronic) 13.0 troubleshooting WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed. • Turn off gas and electrical power before servicing the appliance. •...
  • Page 46 Check that venting is installed correctly. appliances). Room is in negative pressure; increase fresh air supply. troubleshooting symptom problem test solution Pilot will not light. Makes Wiring: short, loose, or damaged Verify the thermocouple/sensor is clean and the wiring is undamaged. Verify the interrupter block is not damaged or too tight.
  • Page 47 Wire connector pins are bent. Straighten pins. Valve wiring is damaged. Replace valve. troubleshooting symptom problem test solution Lights or blower Control module switch in Verify ON/OFF switch is in the “I” position which denotes on. won’t function (if wrong position. equipped).
  • Page 48: Warranty

    Napoleon neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. Napoleon will not be responsible for: over- fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
  • Page 49: Service History

    15.0 service history service history W415-4005 / A / 07.22.21...
  • Page 50 NAPOLEON CELEBRATING OVER 40 YEARS OF HOME COMFORT PRODUCTS 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 Scan this QR code for more information or visit our website at: 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 www.napoleonfireplaces.com/support/gs28...
  • Page 51 IF SEPARATE MANUALS, ADD “PLACE LOGO BARCODE LABEL ON THE OWNER’S MANUAL” Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 SERIENNUMMER VOM KARTON AUFBRINGEN Téléphone 1(866)820-8686 • www.napoleon.com • hearth@napoleon.com $10.00...
  • Page 52: Consignes De Sécurité

    NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot consignes de sécurité viewing glass is provided with this appliance and must be installed for the protection of children and other at-risk AVERTISSEMENT individuals.
  • Page 53 continue de s’éteindre, faire réparer. Garder propres le brûleur et le compartiment de contrôle. • Cet appareil ne devra être modifi é en aucun cas. • Ne laissez pas les ventilateurs souffl er directement sur l’appareil. Empêchez les courants d’air de modifi er consignes de sécurité...
  • Page 54 table des matières information générales branchement du gaz taux et efficacités instructions générales 5.0 finitions information sur la plaque installation / enlèvement de l'écran de d’homologation protection dimensions ouverture et fermeture de la porte installation dans une maison mobile disposition des bûches (modèle GDS28) braises incandescentes évacuation...
  • Page 55: Liste De Vérification

    liste de vérification Installateur, veuillez rempli les informations suivants: Client: _____________________________________________________________________ Addresse: _____________________________________________________________________ Date d'installation: _____________________________________________________________________ Location de l'appareil: _____________________________________________________________________ Installateur: _____________________________________________________________________ Numéro de contact du détaillant / distributeur: _____________________________________________________________________ No. de série: _____________________________________________________________________ Modèle: GDS28-1NEA GDS28-1PEA Gaz naturel: Propane: GS28-1NEA GS28-1PEA 1.0 information générales...
  • Page 56: Instructions Générales

    information générales instructions générales AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Prévoyez un accès suffisant pour entretenir et opérer l’appareil. •...
  • Page 57: Information Sur La Plaque D'homologation

    Recessed depth X” Profondeur d’encastré une face X” L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez au *** Mantel X” from appliance opening *** Tablette X” de l’ouverture de l’appareil manuel d’installation pour les spécifications d’évacuation. Il est nécessaire de bien réinstaller et *** Maximum horizontal extension: *** L’extension horizontale maximale: X”.
  • Page 58 information générales dimensions W415-4005 / A / 07.22.21...
  • Page 59 2.0 évacuation évacuation AVERTISSEMENT • Risque d’incendie. Conservez les dégagements nécessaires au conduit d’évent et à l’appareil. • Les courses horizontales et verticales du système doivent être supportées à tous les 3 pi (0,9m). Utilisez l’ensemble de support mural Wolf Steel W010-0067 ou des attaches incombustibles équivalents afi n de maintenir le dégagement aux matériaux combustibles pour les courses verticales et horizontales.
  • Page 60: Évacuation

    raccordement du conduit d’évacuation à la buse du foyer qui doit être scellé avec le scellant noir à haute température Mill Pac. Le scellant à haute température doit être commandé séparément. évacuation Lorsque vous utilisez les composants d'évacuation Wolf Steel, n'utilisez que des composants d'évacuation Wolf This template must be used in conjunction with templates 7.1.1 or 7.1.2, depending on Steel conjointement avec les ensembles de terminaison suivants: ensemble de terminaison murale GD-175 (7/12"...
  • Page 61: Installations Particulières D'évents

    évacuation installations particulières d'évents 2.2.1 ensemble périscopique Utilisez l’ensemble périscopique afi n de positionner la terminaison au-dessus du niveau du sol. L’ensemble périscopique doit être installé de façon à ce que la fente d’air du bas soit située à un minimum de 12 pouces mble périscopique afi n de positionner la terminaison au-dessus du niveau du sol.
  • Page 62: Fr 2.3 Emplacements Et Dégagements Minimaux De La Terminaison

    évacuation emplacements et dégagements minimaux de la terminaison Applications pour balcon couvert ††* = 3 feet ≤ 15 feet = 2 x ACTUAL (0.9m) (4.6m) note: INSTALLATIONS Les terminaux du mur sont à des fi ns d’illustration seulement. La taille et les formes peuvent varier. Mesures des terminaux prises à...
  • Page 63: Charte D'application Des Évacuations

    évacuation charte d'application des évacuations Évacuation sur le dessus Terminaison horizontale Terminaison verticale La course verticale est La course verticale La course verticale La course verticale plus grande ou égale à est plus petite que la est plus grande ou est plus petite que la course horizontale égale à...
  • Page 64: Fr 2.7 Évacuation Sur Le Dessus - Terminaison Horizontale

    évacuation évacuation sur le dessus - terminaison horizontale ) < (V Confi guration d’évacuation simple Consultez le graphique pour déterminer la (un coude de 90° seulement). course verticale nécessaire V par rapport à la course horizontale requise H 40 (12,2) 39 (11,9) 40 (12,2) 39 (11,9)
  • Page 65 évacuation ) > (V Consultez le graphique pour déterminer la course verticale Configuration d'évacuation simple (un coude de 90° nécessaire V par rapport à la course horizontale requise H seulement). 150 (3810) 147 (3733,8) COURSE VERTICALE 100 (2540) REQUISE EN POUCES (MILLIMÈTRES)V 57 (1447,8)
  • Page 66: Fr 2.8 Évacuation Sur Le Dessus - Terminaison Verticale

    évacuation évacuation sur le dessus - terminaison verticale ) < (V Configuration d'évacuation simple. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 40 (12,2) 30 (9,1) COURSE VERTICALE REQUISE EN 20 (6,1) PIEDS (MÈTRES)V...
  • Page 67 évacuation ) > (V Configuration d'évacuation simple. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 20 (6,1) 19 (5,8) COURSE VERTICALE REQUISE EN 10 (3,1) PIEDS (MÈTRES) V 3 (0,9) (7,6) (9,1) (1,5)
  • Page 68: Terminaison Verticale À Travers Une Cheminée Existante

    évacuation terminaison verticale à travers une cheminée existante AVERTISSEMENT • Risque d’incendie • Les confi gurations d’évacuation coaxiales à colinéaires ne doivent être utilisées que dans une cheminée ou une enceinte de nature incombustible. Une installation dans une enceinte combustible peut causer un incendie. Cet appareil est conçu pour être raccordé...
  • Page 69: Installation

    3.0 installation installation AVERTISSEMENT • Avant d’effectuer les branchements pour l’alimentation en gaz et électronique, assurez-vous de retirer toute composante non fi xée à l’intérieur de la chambre de combustion. • Si votre appareil comprend un système de télécommande, assurez-vous que le récepteur est à la position «...
  • Page 70: Installation Horizontale

    installation note: Si l’appareil est installé directement sur un tapis, sur une surface de vinyle, ou tout autre revêtement de plancher combustible autre que le bois, l’appareil devra être monté sur un panneau continu de métal ou de bois se prolongeant sur toute la largeur et la profondeur 3.1.1 installation horizontale AVERTISSEMENT...
  • Page 71: Installation Verticale

    installation 3.1.2 installation verticale Cette confi guration s’applique lorsque l’évacuation se fait à travers un toit. Des ensembles d’installation pour les différentes pentes de toit sont disponibles chez votre détaillant autorisé. Voir la section « accessoires » dans le manuel du propriétairepour commander l’ensemble spécifi que dont vous avez besoin.
  • Page 72 installation 3.1.4 installation de la terminaison verticale AVERTISSEMENT • Conservez un espace minimale de 2 po (51mm) entre la base de la prise d’air et le collet de solin. Matériel de fi xation fourni avec les ensembles de terminal pour toit et raccord appropriées. Fixez le support de toit au toit à...
  • Page 73: Raccordement Des Évents À L'appareil

    installation REAR VENT TOP VENT - FLEX TOP VENT - RIGID/FLEX raccordement des évents à l'appareil Attachez le tuyau télescopique à la dernière section de conduit #8 X 1/2” #8 X 1/2” rigide. Fixez-le avec des vis et scellez. #8 X 1/2” #8 X 1/2”...
  • Page 74: Installation De L'évent De Type « B

    installation 3.3.3 installation de l'évent de type « B » Suivez les instructions du fabricant de l'évent de type « B » pour l'installation de la cheminée. Enlevez et jetez les deux plaques couvrant les entrées d'air comburant, ainsi que leur joint d'étanchéité, qui se trouvent sur le panneau arrière de l'appareil.
  • Page 75: Ajout De Sections D'évents

    installation 3.3.5 ajout de sections d'évents Ajoutez des sections de cheminée, selon les instructions d’installation du fabricant. Si la cheminée devra dépasser par l’espace grenier un écran protecteur de chevrons ou une bouclier d'isolation du grenier est requis. La cheminée doit dépasser le toit d’au moins 3’...
  • Page 76: Branchement Du Gaz

    4.0 branchement du gaz installation AVERTISSEMENT • Risque d’incendie, d’explosion, ou d’asphyxie. Assurez-vous qu’il n’y ait aucune source d’allumage comme des étincelles ou une fl amme nue. • Soutenez le contrôle du gaz lorsque vous attachez le tuyau pour éviter de plier la conduite de gaz. •...
  • Page 77: Installation / Enlèvement De L'écran De Protection

    5.0 finitions finitions AVERTISSEMENT • Risque d’incendie! • N’obstruez jamais l’ouverture sur le devant de l’appareil. • La façade de l’appareil doit être faite de matériaux incombustibles comme de la brique, du marbre, du granite, etc., à condition que ces matériaux ne se trouvent pas en deçà de la dimension spécifi ée tel qu’illustré. Comme alternative, vous pouvez utiliser le panneau de gypse comme fi nition pour votre appareil, voir les illustrations à...
  • Page 78: Finitions

    finitions ouverture et fermeture de la porte AVERTISSEMENT • La vitre peut être chaude. Ne touchez pas la vitre jusqu’à ce qu’elle ait refroidi. • Les loquets de porte font partie d’un dispositif de sécurité et doivent être adéquatement verrouillés. Ne faites pas fonctionner l’appareil lorsque les loquets sont déverrouillés.
  • Page 79: Disposition Des Bûches

    finitions disposition des bûches AVERTISSEMENT • Omettre de positionner les bûches conformément aux schémas ou omettre d’utiliser uniquement des bûches spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. • Les bûches doivent être placées correctement à l’intérieur de l’appareil. Ne changez pas la position des bûches car l’appareil risque de ne pas fonctionner adéquatement et un retard d’allumage risque de se produire.
  • Page 80: Braises Incandescentes

    finitions braises incandescentes AVERTISSEMENT • Obstruez pas ni fermer les orifi ces du brûleur. Le blocage des orifi ces du brûleur peut créer une fl amme irrégulière, des dépôts de carbone et un retard d’allumage. Déchirez les braises incandescentes en morceaux et placez une couche lâche sur le grillage du brûleur. Les braises devraient être déchirées très soigneusement en petits morceaux minces irréguliers, car seuls les côtés des fi bres exposées à...
  • Page 81: Instructions D'opération / Allumage

    6.0 instructions d'opération instructions d'opération instructions d'opération / allumage L’interrupteur marche/arrêt des modèles GDS28 et GS28 est situé à l’arrière de l'appareil, dans le coin supérieur gauche. Lorsqu’il est allumé pour la première fois, l'appareil dégagera une légère odeur pendant quelques heures. Cela est une condition normale temporaire causée par la cuisson de la peinture et l’évaporation des lubrifiants internes utilisés dans le processus de fabrication;...
  • Page 82: Télécommande

    instructions d'opération dessin générale de la télécommande note: La télécommande est optionnel. L’interrupteur du récepteur doit être en position « REMOTE » pour que la télécommande fonctionne. Le système de télécommande fonctionne par radiofréquences qui sont envoyées par la télécommande au récepteur. Il est recommandé...
  • Page 83 instructions d'opération changeant les piles dans le bloc-pile AVERTISSEMENT • Assurez-vous que l’alimentation électrique et la gaz à l’appareil est éteint. • Assurez-vous que l’appareil est complètement refroidi avant de commencer service. note: En cas d'une panne de courant, votre appareil peut fonctionner utilisant le sauvegarde de pile fourni. Retirez l'écran de protection pour accéder facilement au compartiment de contrôle.
  • Page 84: Schéma De Câblage

    7.0 schéma de câblage instructions d'opération AVERTISSEMENT • Ne raccordez pas l’interrupteur mural ou la soupape de gaz à l’alimentation électrique (110 V). ASSEMBLAGE PILOTE W010-2863 (NG) W010-2900 (P) MODULE D’ALLUMAGE W190-0135 3/16” NOTE: LES ÉTIQUETTES DE FIL SONT ACCROCHÉES LIGNE DE IL DE ÉLECTRODE...
  • Page 85: Fonctionnement

    8.0 fonctionnement opération (électronique) AVERTISSEMENT • Si ces instructions ne sont pas suivies à la lettre, un incendie ou une explosion pourraient s’ensuivre, causant des dommages matériels, des blessures corporelles ou des pertes de vie. • Si applicable, allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée.
  • Page 86: Réglage De La Veilleuse

    9.0 réglages réglages réglage de la veilleuse Ajustez la vis de la veilleuse pour obtenir une fl amme de taille normale. Tournez vers la droite pour réduire l’apport de gaz. Vérifi ez la pression: Pour vérifi er la pression d’arrivée, tournez la vis (A) vers la gauche deux à...
  • Page 87 3/8” - 1/2” 3/8” - 1/2” (9.5mm - 12.7mm) (9.5mm - 12.7mm) réglages Flame must envelop La flamme doit envelopper upper la thermocouple de 3/8" à réglage du venturi 3/8" to 1/2" 1/2" (12.7mm - 9.5mm) of (9.5mm - 12.7mm) L’ouverture du volet d’air a été...
  • Page 88 10.0 entretien entretien AVERTISSEMENT • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. • L’appareil peut être chaud. Attendez qu’il soit refroidi avant d’en faire l’entretien. • N’utilisez pas de produits abrasifs. • Ne peinture pas l’assemblage de la veilleuse. Cet appareil et son système d’évacuation devraient être inspectés avant la première utilisation et au moins une fois l’an par un technicien de service qualifi é.
  • Page 89: Entretien Annuel

    entretien 10.1 entretien annuel AVERTISSEMENT • Le caisson devient trés chaud lors du fonctionnement. Laissez l’appareil se refroidir complétement ou portez des gants antichaleur avant d’effectuer l’entretien. • Ne jamais aspirer des braises qui sont chaudes. • Ne peinturez pas l’assemblage de la veilleuse. •...
  • Page 90 entretien 10.3 remplacement de la soufflerie SOUFFLERIE Le remplacement de la soufflerie peut être fait depuis la chambre de combustion ou depuis le panneau. Nous vous conseillons cette dernière option. INSTALLATION DEPUIS LE PANNEAU ARRIÈRE : blanc POUR LE MODÈLE GDS28 THERMODISQUE •...
  • Page 91: Pièces De Rechange

    pièces de rechange 11.0 pièces de rechange AVERTISSEMENT • Omettre de positionner les pièces conformément à ce manuel ou d’utiliser uniquement des pièces spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. Contactez votre détaillant pour les questions concernant les prix et la disponibilité des pièces de remplace- ment.
  • Page 92 pièces de rechange W415-4005 / A / 07.22.21...
  • Page 93 pièces de rechange W415-4005 / A / 07.22.21...
  • Page 94: Accessoires

    pièces de rechange 12.0 accessoires W415-4005 / A / 07.22.21...
  • Page 95 guide de dépannage 13.0 guide de dépannage AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. •...
  • Page 96: Guide De Dépannage

    guide de dépannage symptôme problème solution La veilleuse ne s’allume Câblage: pénurie, connexion Vérifi ez qu’il n’y a pas de connexions desserrées du thermocouple ni sonde de fl amme. pas. Il y a du bruit mais desserrée (rectifi cation de la Vérifi ez l’interrupteur de bloc n’est pas endommagée ou trop serré.
  • Page 97 fi ls sont courbeés. symptôme problème solution Câblage de la soupape est Remplacez la soupape. guide de dépannage endommagée Moteur tourne, les Les piles du récepteur sont Remplacez les piles. bips fréquent se faibles. symptôme problème solution produit. Lumières ou la souf- Moteur tourne, les L’interrupteur de contrôle est Les piles du récepteur sont...
  • Page 98: Garantie

    garantie 14.0 garantie Les produtits Napoléon sont fabriqués conformément aux normes strictes du Système de Gestion de la Qualité mondialement reconnu ISO 9001 : 2015. Les produits Napoléon sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi és qui sont fi ers de leur travail.
  • Page 99: Historique D'entretien

    garantie 15.0 historique d'entretien W415-4005 / A / 07.22.21...
  • Page 100 NAPOLÉON CÉLÈBRE PLUS DE 40 ANS D’EXISTENCE CONSACRÉS À LA CONCEPTION DE PRODUITS DE CONFORT 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 De Riemsdijk 22, 4004 LC Tiel, Pays-Bas Téléphone: 1-866-820-8686...

Ce manuel est également adapté pour:

Haliburton gs28-1neaHaliburton gds28-1peaHaliburton gs28-1pea