AMR SENSORS- Mode d'emploi / User guide version V1.2
3. Preparation and configuration
3.1. Disassembling the casing
The product is delivered disassembled so that you can access the lower part of the electronics. This part enables the sensor or sensors to be
connected to the screw terminals as well as access to the configuration switches.
Once assembly of the sensors has been finalised and the configuration has been carried out, the casing can be closed.
NB: Once the casing is closed, it will no longer be possible to open it without running the risk of voiding the IP67 protection index guarantee.
3.2. Fitting the packing gland seal
Before connecting your sensor's cable strands to the product's screw terminals, you must insert the packing gland's nut and the seal appropriate
for your configuration.
Three types of seals are supplied with the AMR Sensors unit: For a cable with a diameter of 5 mm, for a cable with a diameter of 3 mm, and for
two cables with diameters of 2.2 mm.
Procédure de montage:
1 - Your sensor and
2 -Pass the cable
its cable
through the packing
gland nut
3.3. Mounting the sensor on the screw terminals
Once the nut and the packing gland seal are fitted, the sensor cables' strands can be connected to the AMR Sensors unit's screw terminals.
Below are the identification details for each terminal:
Note: A maximum of 2 sensors may be used in parallel. The user can choose freely between analogue and digital options
I/O sensor 1
I/O sensor 2
Seal for 1 x 5 mm diam. cable
Seal for 1 x 3 mm diam. cable
3 - Pass the cable
through the packing
107
gland seal
TOR-1
TOR-2
Seal for 2 x 2.2 mm diam. cables
90
4 - Pass the cable
through the AMR SEN-
SORS casing base
I/O sensor(s) direct assembly
27
5 - Fit the O-ring
6 - Connect the sen-
onto the seal of the
sor cable strands to
casing base
the screw terminals
Page
30