Security Distances; Connection - Lincar Alice 480N Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SECURITY DISTANCES

From NOT combustible object :
A > 500 mm
From combustible object and from principal wall in rein forced concrete :
A > 1000 mm
The minimal distance between the stove and every flammable object around it is 1.5
meter.
Mod 470
Mod 480LZ-490LZ

1.4 Connection

Before connection check technical data reported in the technical plate ( Chap. 4 ) and
control that it correspond to the ones required in the order.
All heating biomass equipment especially wood stove has to evacuate the combustion
products in a flue built in conformity with normative in force.
The following instructions describes „ informations for a good installation „ and it refers
to a normative in force but it are not to be consider exhaustive for installations laws.
IT IT IT IT- - - - GB
GB- - - - FR
GB
GB
FR- - - - ES
FR
FR
B > 200 mm
C > 200 mm
B > 350 mm
C > 250 mm
Mod 480N-490N
20/64
ES mod. 470-480LZ-490LZ-480N-490N
ES
ES
D > 1500 mm
D > 1500 mm
Valid for all the Models
To measure from apparatus
external surface for every models

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Alice 490nGioia 470Alice 480lzAlice 490lz

Table des Matières