Technical parameters

Model
Operating temperature range
(°C)
Performance conditions: Air 27°C, Water 27°C, Humidity 80%
Max. swimming pool volume
(m
)
3
Heating capacity (kW)
COP
Performance conditions: Air 15°C, Water 26°C, Humidity 70%
Max. swimming pool volume
(m
)
3
Heating capacity (kW)
COP
Technical specifications
Rated input power (kW)
Rated input current (A)
Maximum input current (A)
Electrical power supply
Minimum water flow rate
(m
/h)
3
Hydraulic connection (mm)
Noise at 10m (dB)
Net weight (kg)
NSH35s
10~43
20
3.5
5.0
12
2.4
3.8
0.63
2.7
4.0
230V 50Hz
1~2
32/38
26
26
6
NSH55s
32
5.6
5.9
20
3.5
4.1
0.85
3.7
6.5
2~2.5
27
36