Auxiliary Load Connection Requirements

ELECTRICAL SHOCK HAZARD
Due to the potential risk of fire, electric shock, or
injuries to persons, Zodiac
loads must be installed in accordance with the
National Electrical Code
and safety codes, and the occupational Safety and
Health Act (OSHA). Copies of the NEC may be
ordered from the National Protection Association, 470
Atlantic Ave., Boston, MA 02210, or from your local
government inspection agency.
In Canada, Zodiac Pumps must be installed in
accordance with the Canadian Electrical Code (CEC).
• The Auxiliary Load relay contacts are rated at
230V/11A RMS. Please ensure the requirements
of the equipment to be connected to the Auxiliary
Load do not exceed this rating.
1
2
TP133
TP130
/100
TP127
L1
GFCI-
(Black)
Protected
230V
Power
L2
Source 2
(Red or Black)
Line
(Black)
230V
Earth
Auxiliary
Load
Note: Recommended Wiring Configuration
Figure 9.
230V Auxiliary Load, Separate Power
Source Wiring Diagram
Jandy
WARNING
Pumps and any auxiliary
®
(NEC
), all local electrical
®
®
L2 L1
L1
F1015
F1014
GFCI-
(Black)
Protected
230V
Power
L2
Source 1
(Red or
Black)
Earth
Pro Series ePump™ Series Pump | Installation and Operation Manual
®
TP133
TP130
/100
TP127
GFCI-
Protected
115V
Power
Source
Earth
Figure 10. 115V Auxiliary Load, Separate Power

Auxiliary Load Operation Characteristics

Auxiliary Load relay contact activation is speed-
dependent, and behaves as follows:

Contact Closure

From a stopped condition, there is a three-minute
delay before the Auxiliary Load contact is closed when
the motor speed reaches and maintains a speed of at
least 1725 RPM.
From a running condition at below 1725 RPM, there
is a five-second delay before the Auxiliary Load contact
is closed when the motor speed reaches and maintains a
speed of at least 1725 RPM.

Contact Opening

If the pump speed is below 1725 RPM, the
Auxiliary Load contact is opened. Contact openings are
always immediate.
1
2
L2 L1
F1015
Earth
Line
(Black)
Neutral
(White)
Line
(Black)
115V
Auxiliary
Load
Sources Wiring Diagram
L1
F1014
GFCI-
(Black)
Protected
230V
Power
L2
Source
(Red or
Black)