6.3) MANUAL SEARCH FOR DISTANCE "0":
The "manual search for distance 0" is carried out with this procedure, that is, you programme the maximum closing point.
This point must always be defined first as it is used as a reference for all the other distances.
As distance "0" is defined in both motors, dip switch configuration will vary according to the motor wanted.
1) Set the dip switches selecting first one motor and then the other in the following way
1 2 3 4 5 6 7 8 9 10
Motor no.1
2) Press the OPEN or CLOSE key (and the <<>> key to increase speed of the motor selected) until the distance wanted is
reached.
OPEN
CLOSE
3) Once the distance wanted is reached for the first motor and then for the second, carry out the "Memorising procedure"
Chap. 6.1
6.4) MANUAL SEARCH FOR DISTANCE "S":
With this procedure you carry out the "manual search for distance "S" which is the point the gate (moved by the 2nd motor)
must reach in opening before the gate moved by the 1st motor can start.
This search is only done with the 2nd motor because it is the first that starts in opening.
If you would like the motors to start together (S=0), memorise without moving the motors.
1) Set the dip switches as follows:
2) Press the OPEN or CLOSE key (and the <<>> key to increase speed of the motor selected) until the distance wanted is
reached.
OPEN
CLOSE
3) Once the distance wanted is reached carry out the "Memorising procedure" Chap. 6.1