Campbell Hausfeld CE7002 Mode D'emploi page 6

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
Installation (Continued)
inStalling a SHut-off valve
A shut-off valve should be installed on the discharge port of the
tank to control the air flow out of the tank� The valve should be
located between the tank and the piping system�
As shown in Figure 3, assemble the outlet valve to the pipe
nipple� Install assembled valve in either end of the tank� Use
thread sealant tape on threads of pipe nipple to prevent air leaks�
Never install a shut-off valve between the
compressor pump and the tank. Personal injury
and/or equipment damage may occur. Never use reducers in discharge
piping.
When creating a permanently installed system to distribute
compressed air, find the total length of the system and select
pipe size from the chart. Bury underground lines below the
frost line and avoid pockets where condensation can gather and
freeze. Apply air pressure to the piping installation and make
sure all joints are free from leaks BEFORE underground lines are
covered. Before putting the compressor into service, find and
repair all leaks in the piping, fittings and connections�
piping
Never use plastic (PVC) pipe for compressed air.
Serious injury or death could result.
Any tube, pipe or hose connected to the unit must be able to
withstand the temperature generated and retain the pressure. All
pressurized components of the air system must have a pressure
rating of 200 psi or higher� Incorrect selection and installation
of any tube, pipe or hose could result in bursting and injury�
Connect piping system to tank using the same size fitting as the
discharge port�
Starter Solenoid (unit WitH eleCtriC Start only)
1� Disconnect negative cable from battery terminal before
attaching wires to the solenoid�
2. Remove the 1/4 inch nut from the left stud. Do not make
contact with the right stud to avoid possible engine ignition�
3. Attach the positive (red) battery cable to the left stud and
reinstall the 1/4 inch nut� Tighten the nut one full turn after it
is finger tight (See Figure 5).
4. Attach the negative (black) battery cable to a convenient
ground� The best place is at the engine mounting bolt� Other
secure places on the engine are suitable�
5. Reattach the negative cable to the battery.
Failure to install appropriate water / oil removal
equipment may result in damage to machinery
or workpiece.
6
www.CH-Commercial.com
discharge port
figure 3 - Shut-off valve install
MiniMuM pipe Size for CoMpreSSed air line
CfM
25 feet
10
1/2 inch
20
3/4 inch
40
3/4 inch
figure 4 - Shut-off valve
left Stud
positive (red)
battery Cable
figure 5 - Starter Solenoid
outlet valve
pipe nipple
length of piping System
50 feet
100 feet
1/2 inch
3/4 inch
3/4 inch
3/4 inch
1 inch
1 inch
fuel tank
250 feet
3/4 inch
1 inch
1 inch

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ce7003Ce7004

Table des Matières