Required Tools For Installation - Haier GE Appliances USYF09UCDWA Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions
Specifications
Indoor
Rated Cooling Capacity Btu/hr
Rated Heating Capacity Btu/hr
Voltage, Cycle, Phase V/Hz/-
Airflow (Turbo/High/Med/Low/Quiet) CFM
Indoor Sound Level dB (Turbo/High/Med/Low/
Quiet)
Chassis Dimension: HxWxD in (mm)
Weight (Ship/Net)-lbs (kg)
Liquid / Suction O.D. in
Drainpipe Size O.D. in (mm)

Required Tools for Installation

14/4 AWG stranded wire
5/8" (16mm), 7/8" (22mm), 1" (25mm) or
adjustable wrench
R-410A refrigerant*
Adhesive tape
Conduit cable clamp 1/2"*
Copper line set
#2 phillips screwdriver
Drill
R-410A flaring tool
Hex wrench
Hole saw 2 1/4"
4
USYF09UCDWA
9,000
10,000
264/235/205/176/147
40/32/25/20
1/4 3/8
Insulation*
Refrigerant scale
Level
Manifold gauge set
Measuring tape
Micron gauge
Mini-split adapter (5/16"F to 1/4"M)
Nitrogen*
Pipe cutter
PVC pipe (optional)
Razor knife
Reamer
USYF12UCDWA
12,000
13,000
208-230/60/1
294/264/235/205/176
42/34/26/21
23.6/27.5/8.7(600/700/220)
36/40 (16.5/18.5)
1/4 3/8
φ 5/8 (16.5)
Saddle clamp (L.S.) w/screws
Sealant, non-expanding (for lineset hole)
Soap/water solution* or gas leakage detector
Stud finder
Torque wrench
Vacuum pump
Wire strippers
All usual and customary HVAC hand and
power tools, meters, and testing devices
*consumable
USYF18UCDWA
15,000
18,000
341/311/282/252/223
46/37/33/28
1/4 1/2
31-5000496 Rev. 2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ge appliances usyf12ucdwaGe appliances usyf18ucdwa

Table des Matières