USE THIS INFORMATION IN ADDITION TO THE PUMP INSTALLATION DATA

Owner's Information

Owner's Information
Serial #:
Motor #:
Installation Date:
HP:
Phase:
Volts:

SAFETY INSTRUCTIONS

TO AVOID SERIOUS OR FATAL PERSONAL INJURY
OR MAJOR PROPERTY DAMAGE, READ AND FOL-
LOW ALL SAFETY INSTRUCTIONS IN MANUAL AND
ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE IN-
STALLATION AND OPERATION OF THIS UNIT AND
MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump or
in the manual, look for one of the fol-
lowing signal words and be alert to the
potential for personal injury or property
damage.
Warns of hazards that WILL cause serious
DANGER
personal injury, death or major property
damage.
Warns of hazards that CAN cause serious
WARNING
personal injury, death or major property
damage.
Warns of hazards that CAN cause personal
CAUTION
injury or property damage.
NOTICE: INDICATES SPECIAL INSTRUCTIONS
WHICH ARE VERY IMPORTANT AND MUST BE
FOLLOWED.
THOROUGHLY REVIEW ALL INSTRUCTIONS
AND WARNINGS PRIOR TO PERFORMING ANY
WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
Important notice: Read safety instructions before proceeding with
any wiring.
All electrical work must be performed
WARNING
by a qualified technician. Always follow
the National Electrical Code (NEC), or the Canadian
Electrical Code, as well as all local, state and provincial
codes. Code questions should be directed to your local
electrical inspector. Failure to follow electrical codes and
OSHA safety standards may result in personal injury or
equipment damage. Failure to follow manufacturer's
installation instructions may result in electrical shock, fire
hazard, personal injury or death, damaged equipment,
provide unsatisfactory performance, and may void manu-
facturer's warranty.
2
PROVIDED BY PUMP MANUFACTURER.
CentriPro motors are not designed for use
WARNING
in swimming pools, open bodies of water,
hazardous liquids, or where flammable gases exist. Well
must be vented per local codes.
Disconnect and lockout electrical power
WARNING
before installing or servicing any electrical
equipment. Many motors are equipped with automatic
thermal overload protection which may allow an over-
heated motor to restart unexpectedly.
All three phase (3Ø) controls for sub-
CAUTION
mersible motors must provide Class 10,
quick-trip, overload protection.
Do not lift, carry or hang motor by the
WARNING
electrical cables. Damage to the Electri-
cal Cables can cause shock, burns or death.
Use only stranded copper wire to pump/
WARNING
motor and ground. The ground wire
must be at least as large as the power supply wires. Wires
should be color coded for ease of maintenance and
troubleshooting.
Install wire and ground according to the
DANGER
National Electrical Code (NEC), or the
Canadian Electrical Code, as well as all local, state and
provincial codes.
Install an all leg disconnect switch where
WARNING
required by code.
The electrical supply voltage and phase
WARNING
must match all equipment requirements.
Incorrect voltage or phase can cause fire, motor and
control damage, and voids the warranty.
All splices must be waterproof. If using
WARNING
splice kits follow manufacturer's instruc-
tions.
Select the correct type and NEMA grade
WARNING
junction box for the application and
location. The junction box must ensure dry, safe wiring
connections.
Failure to permanently ground the pump,
WARNING
motor and controls before connecting to
power can cause shock, burns or death.
4" motors ≥ 2 HP require a minimum
WARNING
flow rate of .25 ft/sec. or 7.62 cm/sec. past
the motor for proper motor cooling. The following are
the minimum flows in GPM per well diameter required
for cooling: 1.2 GPM/4", 7 GPM/5", 13 GPM/6", 20
GPM/7", 30 GPM/8" or 50 GPM in a 10" well. Pumps
≥ 2 HP installed in large tanks should be installed in a
flow inducer sleeve to create the needed cooling flow or
velocity past the motor.
All motors require a minimum 5'
CAUTION
submergence for proper refill check valve
operation.
This motor has been evaluated for use
CAUTION
with Water Only.