Routine Maintenance

To ensure proper unit operation, the air filter should be cleaned at least
monthly, and more frequently if conditions warrant. The unit must be turned
off before the filter is cleaned.
To Remove, Wash and Replace Filter
Lower front panel (see Figure 2). Use handle on filter to flex filter up and
out of retainer. Remove filter from unit (see Figure 3). Clean filter monthly
or more frequently if needed. Refer to accessories section for filter options.
Coils & Chassis
NOTE:
Do not use a caustic cleaning agent on coils or base pan. Use a
biodegradable cleaning agent and degreaser. The use of harsh
cleaning materials may lead to deterioration of the aluminum fins
or the coil end plates.
The indoor coil and outdoor coils and base pan should be inspected
periodically (annually or semi-annually) and cleaned of all debris (lint,
dirt, leaves, paper, etc.) as necessary. Under extreme conditions, more
frequent cleaning may be required. Clean the coils and base pan with a
soft brush and compressed air or vacuum. A pressure washer may also be
used; however, you must be careful not to bend the aluminum fin pack. Use
a sweeping up and down motion in the direction of the vertical aluminum fin
pack when pressure cleaning coils.
NOTE:
It is extremely important to insure that none of the electrical
and/ or electronic parts of the unit get wet. Be sure to cover all
electrical components to protect them from water or spray.
Decorative Front
Use a damp (not wet) cloth when cleaning the control area to prevent water
from entering the unit, and possibly damaging the electronic control.
The decorative front and the cabinet can be cleaned with warm water and a
mild liquid detergent. Do NOT use solvents or hydrocarbon based cleaners
such as acetone, naphtha, gasoline, benzene, etc.
The indoor coil can be vacuumed with a dusting attachment if it appears
to be dirty. DO NOT BEND FINS. The outdoor coil can be gently sprayed
with a hose if you can get to it. If not, you might call your dealer for a more
thorough cleaning when needed.
The air filter should be inspected weekly and cleaned if needed by vacuuming
with a dust attachment or by cleaning in the sink using warm water and a
mild dishwashing detergent. Dry the filter thoroughly before reinstalling. Use
caution, the coil surface can be sharp.
Fan Motor & Compressor
The fan motor & compressor are permanently lubricated, and require no
additional lubrication.
Wall Sleeve
Inspect the inside of the wall sleeve and drain system periodically (annually
or semi-annually) and clean as required. Under extreme conditions, more
frequent cleaning may be necessary. Clean both of these areas with an
antibacterial and antifungal cleaner. Rinse both items thoroughly with water
and ensure that the drain outlets are operating correctly. Check the sealant
around the sleeve and reseal areas as needed.

Service and Assistance

Before calling for service, please check the "Troubleshooting Tips" section on
Pages 38 and 39. This may help you to find the answer to your problem,
avoid unnecessary service calls, and save you the cost of a service call if
the problem is not due to the product itself. If you have checked the "Basic
Troubleshooting" section and still need help, it is available as follows:
You can find the name of your local Authorized Service Provider by visiting our
website at www.friedrich.com.
If you require further assistance
You can call the Customer Support Call Center at 1-800-541-6645.
Before calling, please make sure that you have the complete model and serial
number, and date of purchase of your equipment available. By providing us
with this information, we will be better able to assist you.
Our specialists are able to assist you with:
Specifications and Features of our equipment.
Referrals to dealers, and distributors.
Use and Care Information.
Recommended maintenance procedures.
Installation information.
Referrals to Authorized Service Providers and Parts depots.

Available Accessories

DC-2 Drain Kit – Part No. 01900235
In some installations, excess condensate water caused by extremely humid
conditions, may result in an undesirable water drip such as on a patio or over
an entryway. MODEL DC-2 DRAIN KIT (Part No. 01900-235) can be installed
to drain excess condensation to an alternate location.
Carbon Filter Kits
The kits vary depending on the chassis size (small, medium, large). Each kit
contains three (3) filters.
KWCFS – Carbon filter kit for small chassis models.
KWCFM – Carbon filter kit for medium chassis models.
KWCFL – Carbon filter kit for large chassis models.
FriedrichLink
Adapter Accessory
KWIFI –
FriedrichLink
Adapter Accessory for wireless control and
additional programming options.
Decorative Color Front Panel Kits
The kits vary depending on the chassis size (small, medium, large).
KWBGE(S/ M/ L)A – S/ M/ L Decorative Front Cover in Classic Beige
KWBLK(S/ M/ L)A – S/ M/ L Decorative Front Cover in Black Onyx
KWBLU(S/ M/ L)A – S/ M/ L Decorative Front Cover in Cobalt Blue
KWPNK(S/ M/ L)A – S/ M/ L Decorative Front Cover in Pink Diamond
KWRED(S/ M/ L)A – S/ M/ L Decorative Front Cover in Deep Red
KWWHT(S/ M/ L)A – S/ M/ L Decorative Front Cover in Designer White
Window Installation Kits
(Standard in Kühl Models without Heat)
KWIKS – For all KES and KHS models.
KWIKM – For all KEM and KHM models.
KWIKL – For all KEL and KHL models.
See www.friedrich.com for additional accessories for your unit.