Please take a few moments each year to perform the following preventive maintenance inspection on your fan
to ensure its safe and efficient operation using the Annual Maintenance Checklist.

Annual preventive maintenance

1.
Check the upper safety cable and shackle. The cable should be wrapped tightly around the building
structure, leaving as little slack as possible. The shackle should be securely tightened and located on the
topside of the structure.
2. Check the two lower safety cables. The cables should be attached from the main fan unit to the bottom of
the extension tube (or to the angle irons for fans mounted directly to angle irons). Ensure all bolts securing
the lower safety cables are torqued to 40 ft·lb (54.2 N·m).
3. Make sure all mounting bolts are present and torqued to 40 ft·lb (54.2 N·m).
4. Inspect motor terminations inside the motor junction box and tighten if necessary.
5. Check the gear reducer for oil leakage. If leakage is present, contact Customer Service.
6. Remove the airfoils and inspect the hub, hub tabs, airfoil retainers, and airfoils for signs of damage or cracks.
7. Reinstall the airfoils using the airfoil retainers, ensuring all bolts are torqued to 29 ft·lb (39.3 N·m).
8. Ensure the bolts securing the winglets to the airfoils are securely tightened.
9. Inspect the whole fan for signs of corrosion, discoloration, pitting, or flaking of metal.

General preventive maintenance

☐ Check all connections at the VFD and tighten as needed. Using a vacuum, remove all dust and debris from
the inside and outside of the VFD.
☐ Verify proper fan rotation. The fan should be rotating counterclockwise when viewed from the floor.
☐ Remove the airfoils and inspect the hub, hub tabs, airfoil retainers, and airfoils for signs of damage or cracks.
☐ Reinstall the airfoils using the airfoil retainers, ensuring all bolts are torqued to 29 ft·lb (39.3 N·m).
☐ Dust the airfoils, motor, and motor housing. If desired, use a gentle cleaner or degreasing agent to polish
the airfoils. Do not use Clorox
fumes.
☐ Observe the motion of the fan during operation. The fan should not wobble or gyrate. If any wobble is
noticed, ensure the mounting structure is rigid enough to support the fan. Contact Customer Service if
wobbling persists.