Les langues disponibles

Action
Exit
AUTODRY OOR LOW
Condition
Action
Exit
OVER TEMPERATURE DETECTED
Condition
Action
Exit
OVERHEAT SENSOR SHORT
Condition
Action
Exit
OVERHEAT SENSOR OPEN
Condition
Action
Exit
8514-291-001 REV E PAGE 32
When detected, there is a delay of 5 minutes before the error is active. When
active, the control will display the "AUTODRY COMMUNICATION ERROR 3"
prompt and the current drying stage will end. The next stage will begin, and
the error will continue to be displayed alternating with the Cycle Progress
screen during the remainder of the stage.
The Error Code will continue to be displayed until the cycle is stopped and the
control is returned to Idle mode.
This error occurs when the machine control sees output from the RMC sensor
(secondary) board that is out-of-range at 300mV or lower.
When detected there is a delay of 5 minutes before the error is active. Once
active, the control will display the "AUTODRY OOR LOW" prompt and the
current drying stage will end. The next stage will begin, and the error will
continue to be displayed alternating with the Cycle Progress screen during the
remainder of the stage.
The Error Code will continue to be displayed until the cycle is stopped and the
control is returned to Idle mode.
This error occurs when an overheat condition has been detected at the OHP
sensor
When detected there is a calculated delay before the error is active. Once
active, the control turns off the heating relays, the control buzzer is turned on,
and the alarm relay closes. After 5 seconds, tumbler rotation may occur. If the
dryer is equipped with a Fire Suppression system, water may be injected into
the dryer cylinder.
The Error Code will continue to be displayed until the condition is no longer
present and the mechanical Reset button is pressed on the Main Control board.
This error occurs when the control detects a short circuit from the overheat
temperature sensor.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met.
The machine will not start, and the Error Code will continue to be displayed
until the condition is no longer present. Once the condition is removed, the
machine still will not start, and the Error Code will continue to be displayed until
the prompt is followed to Reset the Error and return the machine to Idle Mode.
This error occurs when the control detects an open circuit from the overheat
temperature sensor.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met.
The machine will not start, and the Error Code will continue to be displayed
until the condition is no longer present. Once the condition is removed, the
machine still will not start, and the Error Code will continue to be displayed until
the prompt is followed to Reset the Error and return the machine to Idle Mode.