Exit
MODEL JUMPER CHANGED
Condition
Action
MODEL JUMPER DRIVE SIZE MISMATCH
Condition
Action
Exit
MODEL JUMPER/ DRIVE PARAMETER
Condition
Action
Exit
NON-DEXTER DRIVE
Condition
Action
Exit
DRIVE OVERCURRENT
Condition
Action
Exit
8514-291-001 REV E PAGE 29
This error occurs when there is no connection to Ground (Pin 7) on the Model
Jumper Header.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met. The machine control checks for
this condition when power is cycled and before starting every machine cycle.
The machine will not start, and the Error Code will continue to be displayed
until the condition no longer exists and the prompt is followed to Reset the
Error Code and return the Machine to Idle Mode.
This error occurs when the jumper connections to Ground (Pin 7) on the Model
Jumper Header have changed since the last control check.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met. The machine control checks for
this condition when power is cycled and before starting every machine cycle.
The machine will not start, and the Error Code will continue to be displayed
until the condition no longer exists and the prompt is followed to Reset the
Error Code and return the Machine to Idle Mode.
This error occurs when the jumper connections to Ground (Pin 7) on the Model
Jumper Header do not match the VFD size code.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met. The machine control checks for
this condition when power is cycled.
The machine will not start, and the Error Code will continue to be displayed
until the condition no longer exists and the prompt is followed to Reset the
Error Code and return the Machine to Idle Mode.
This error occurs when the jumper connections to Ground (Pin 7) on the Model
Jumper Header do not match the VFD parameters being used.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met. The machine control checks for
this condition when power is cycled.
The machine will not start, and the Error Code will continue to be displayed
until the condition no longer exists and the prompt is followed to Reset the
Error Code and return the Machine to Idle Mode.
This error occurs when a non-Dexter VFD is installed in the machine.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met. The machine control checks for
this condition when power is cycled and before starting every machine cycle.
The machine will not start, and the Error Code will continue to be displayed
until the condition no longer exists and the prompt is followed to Reset the
Error Code and return the Machine to Idle Mode.
This error occurs when the control receives a message that the drive has
experienced an over current condition.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met.
The machine will not start, and the Error Code will continue to be displayed
until the condition no longer exists and the prompt is followed to Reset the
Error Code and return the Machine to Idle Mode.