Action
Exit
DRIVE COMMUNICATION
Condition
Action
Exit
DRIVE ENABLE
Condition
Action
Exit
OUT OF SERVICE
Condition
Action
Exit
AUTODRY COMMUNICATION 1
Condition
Action
Exit
AUTODRY COMMUNICATION 2
Condition
Action
Exit
AUTODRY COMMUNICATION 3
Condition
8514-291-001 REV E PAGE 31
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met.
The machine will not start, and the Error Code will continue to be displayed
until the condition no longer exists and the prompt is followed to Reset the
Error Code and return the Machine to Idle Mode.
This error occurs the control cannot communicate with the VFD.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met.
The machine will not start, and the Error Code will continue to be displayed
until the condition no longer exists and the prompt is followed to Reset the
Error Code and return the Machine to Idle Mode.
This error occurs when the control sees a message that the VFD Enable circuit
is not closed.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met.
The machine will not start, and the Error Code will continue to be displayed
until the condition no longer exists and the prompt is followed to Reset the
Error Code and return the Machine to Idle Mode.
This error occurs when the user has designated that the machine control
should be made inoperable.
When detected, the control turns off the motor and the heating relay. There is
no delay in the action once the criteria are met.
The machine will not start, and the Error Code will continue to be displayed the
user changes the Out of Service state.
This error occurs when the machine control does not detect CAN
communication from the RMC stationary (primary) board.
When detected, there is a delay of 30 5 seconds before the error is active.
When active, the control will display the "AUTODRY COMMUNICATION ERROR
1" prompt and the Error Code will continue to be displayed until the cycle ends
and the machine returns to Idle Mode.
The Error Code will continue to be displayed until the cycle is stopped and the
control is returned to Idle mode.
This error occurs when the machine control does not detect wireless
communication between the RMC stationary (primary) board and RMC rotating
(secondary).
When detected, there is a delay of 5 minutes before the error is active. When
active, the control will display the "AUTODRY COMMUNICATION ERROR 2"
prompt and the current drying stage will end. The next stage will begin, and
the error will continue to be displayed alternating with the Cycle Progress
screen during the remainder of the cycle.
The Error Code will continue to be displayed until the cycle is stopped and the
control is returned to Idle mode.
This error occurs when the machine control does not detect adequate data
from the RMC stationary (primary) board.

Publicité