Ignition And Start Up; Do A Test Of The Gas Safety Valve - Norcold N109 Serie Manuel D'installation

Masquer les pouces Voir aussi pour N109 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Ignition and Start Up

Before ignition or start up of the refrigerator:
- Make sure the air flow in the lower intake vent, through the refrigerator coils and condenser, and out the upper exhaust vent is not
blocked or decreased.
- Make sure there are no combustible materials in or around the refrigerator.
Ignition and start up: (See Art01018)
If the gas does not ignite in 30 seconds, the
NOTICE
gas safety valve of the refrigerator automati-
cally closes and the controls either select a
different energy source or "no" "FL" appears in
the center display. This means that the gas did
not ignite.
If the gas does not ignite after several attempts, refer to the
"Fault Codes" section of this manual.
Automatic Mode Operation:
1. Push the ON/OFF button [30] to start the refrigerator.
2. Push the MODE button [31] until "AU" appears in center display [33].
3. Push the TEMP SET button [32] as needed to set the thermostat at "4-6" temperature setting.
- If "AU" "AC" appears in the center display, it means that:
- 120 volt AC power is available to the refrigerator.
- The refrigerator is operating on AC electric power.
- After ten seconds, the "AU" "AC" goes off and only a green dot "." remains to show that the refrigerator is operating.
- If "AU" "LP" appears in the center display, it means that:
- 120 volt AC power is not available to the refrigerator.
- The refrigerator is operating on propane gas.
- After ten seconds, the "AU" "LP" goes off and only a green dot "." remains to show that the refrigerator is operating.
Manual Mode Operation:
1. Push the ON/OFF button [30] to start the refrigerator.
2. Push the MODE button [31] until "LP" shows in the center display [33].
3. Push the TEMP SET button [32] to set the thermostat at "4-6" temperature setting.
4. The "LP" remains until you select a different operating mode or shut down the refrigerator.

Do a test of the gas safety valve:

1. Start up the refrigerator in the manual mode operation.
2. Open the lower intake vent.
3. Remove one wire from the solenoid of the gas safety valve at the rear of the refrigerator.
Art01018
1-COLD COLDEST-9
MODE
ON-OFF
ON
TEMP
SET
33
32
Installation Manual 21
31
30

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

N109 im serie

Table des Matières