Maintenance - Bosch 300 Serie Manuel D'utilisation

Masquer les pouces Voir aussi pour 300 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

To reinstall the ventilation filter, slide it into the side
3.
slot, then push up and toward oven to lock. Reinstall
the 2nd filter using the same procedure.

Maintenance

Surface light replacement
CAUTION
9
To avoid risk of personal injury or property
damange, wear gloves when replacing the light
bulbs.
Unplug the microwave oven or turn off power at the
1.
main circuit breaker.
Remove the bulb cover mounting screws at both light
2.
positions under the microwave.
Replace bulb with 30 watt appliance bulb.
3.
Replace bulb cover and mounting screw.
4.
Plug the microwave back into the power supply or turn
5.
the power back on at the main circuit breaker.
Oven light replacement
To replace light bulb, first disconnect power to the
1.
microwave oven at the circuit breaker panel or by
unplugging.
Remove the vent grill mounting screws.
2.
Pull the vent grill away from the unit.
3.
Remove the charcoal filter by pushing it inwards, then
4.
turn and pull it away from the unit.
Open light cover located behind filter mounting by
5.
carefully pulling up on the front edge.
19

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hmv3052c

Table des Matières