Télécharger Imprimer la page

Coxreels 1125 Serie Manuel D'installation Et D'entretien page 3

Publicité

Les langues disponibles

Les langues disponibles

FIGURE 1.0
WARNING: READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE, OR MAINTAIN THIS PRODUCT. ONLY QUALIFIED
PERSONNEL SHOULD UNDERTAKE THE INSTALLATION AND COMMISSIONING OF THIS PRODUCT. FAILURE TO COMPLY WITH INSTRUCTIONS COULD
RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE.
WARNING: REEL SHOULD NOT BE INSTALLED ABOVE 15 FEET MAXIMUM FROM THE FLOOR.
MOUNTING OF REEL
Overhead installation mountings should be such that the reel is not
supported by bolts in tension. A safety chain, cable, enclosure or
netting is strongly recommended to minimize damage and/or possible
injury in the event of a mounting failure.
To mount reel to a solid structure use 7/16" or M12 bolts, washers,
and nuts. Masonry bolts may be used depending on mounting
application. Mounting hardware is NOT provided. Mounting patterns
will vary depending on model.
Fit mounting hardware to ceiling/wall/floor so reel can be fastened
into position. Fit reel and tighten all hardware securely.
INSTALLATION OF INLET HOSE
Apply thread sealant to inlet hose and connect to the swivel joint on
reel.
CAUTION: IT IS IMPORTANT TO USE A "FLEXIBLE" INLET HOSE.
DO NOT USE SOLID PIPING OR RESTRAIN INLET HOSE AS TO
CAUSE ANY SIDE FORCE ON SWIVEL JOINT. THE WARRANTY IS
VOID IF NOT PROPERLY INSTALLED.
Flush some product through the system before connecting inlet hose
to the source. Connect end to supply source.
Install inlet hose into swivel assembly by hand tightening, followed by
½ turn with wrench. DO NOT over tighten as it may damage swivel.
INSTALLATION OF CABLE (1125WC SERIES)
NOTE: Before proceeding, ensure that you are installing the proper size,
length and type of hose that the reel is rated for. Consult factory if
unsure of rating.
CAUTION: ENSURE THAT THE CABLE CONNECTOR IS SECURELY
CRIMPED, SOLDERED, OR CLAMPED TO CABLE.
Place connector over stud (fig 3.0) and install brass nut (supplied).
Using a wrench, firmly hold onto the nut under the connector while
tightening the outer nut.
Connect the supply line in the same manner.
For assembly drawings, parts lists, or specific repair instructions, refer to web site at
INSTALLATION AND MAINTENANCE MANUAL
INSTALLATION
Coxreels, Inc., 5865 S. Ash Ave., Tempe, Arizona, USA, 85283
FIGURE 2.0
INSTALLATION OF OUTLET HOSE
NOTE: Before proceeding, ensure that you are installing the proper size, length
and type of hose that the reel is rated for. Consult factory if unsure of rating.
Securely install hose reel prior to installing outlet hose.
Apply thread sealant to male hose fitting and insert into the drum
opening. Note: It is recommended that a swivel type connector be
used to ease installation of outlet hose.
Thread male hose fitting into outlet riser(s). Refer to figure 1.0 for
single and figure 2.0 for double outlets. Note: Outlet riser is
removable on 1195 series.
Using a wrench, firmly hold on to riser fitting while tightening hose
connector.
CAUTION: FULLY EXTEND AND CHARGE HOSE BEFORE
INITIALLY WINDING ON TO REEL. THIS PREVENTS FLATTENING
OF HOSE AND EXCESSIVE PRESSURE ON DRUM WHEN HOSE IS
FULLY CHARGED DURING OPERATION.
Wind hose on to reel; operator should hand guide the hose on to reel
to achieve maximum capacity.
Flush fluid through system. Inspect hose, connections, and swivel for
leaks.
HOOK-UP ELECTRICAL MOTOR
CAUTION: REMOVE ALL ELECTRICAL POWER WHEN WIRING. DO
NOT HOT WIRE. OBSERVE ALL APPLICABLE NEC, OSHA, AND
LOCAL CODES.
Ensure motor location is conducive to mounting or operating requirements.
Field modifications are not recommended.
Ensure power supply and motor voltage ratings are compatible. Refer to
figures 4.0, 5.0, and 6.0 for wiring diagrams.
Install switch, solenoid, circuit breaker, etc. as required. Consult factory for
optional components.
Apply power, and inspect reel to determine proper operation.
Page 3 of 5
www.coxreels.com
Tel: 1-800-269-7335
FORM #PM-004 REV E 09/13
FIGURE 3.0
or consult factory.