Attention!
If the eccentric worm-drive pump is operated against a closed outlet,
an appropriate by-pass (pressure relief) valve must be used to limit
the maximum pressure.
Attention!
Only turn on the pump when it is in the liquid. Never operate the
pump dry.
We recommend the installation of a device to protect the pump
against dry running such as a flow control, contact manometer,
differential pressure switch, level control or similar appropriate
devices.
Avoid the operation at closed suction side.
Only use the pump for its intended purpose.
Never leave the pump unattended.
The pump has to be used in vertical position only (except for
horizontal versions).
Install the pump in a way that ensures that it cannot fall into the
container.
Only use the pump with a suitable hose.
The pump should not be exposed to the weather.
The pump should not be immersed deeper into the liquid than the
outlet connection.
Clean pump after each operation.
Attention!
Immerse the pump into the liquid and secure it in a vertical position
by the use of a barrel fitting or a screw clamp. Always position the
pump to prevent it from falling into the container.
Attention!
We recommend providing the power supply with fault current
breakers.
Attention!
Firmly tighten the screws resp. the union nut.
Attention!
Ensure that the hose is securely fixed to the hosetail.
If the hose is completely emptied, the air compressed in the hose
can cause a loud bang when suddenly released.
Attention!
Check connections for tightness.