Voltage Requirements
12.8 VDC / 24 VDC
Minimum (cut-out) ......................................................................... 10.9 VDC / 23.8 VDC
Restart (cut-in) .............................................................................. 12.2 VDC / 25.2 VDC
Maximum ...................................................................................... 17.0 VDC / 31.5 VDC
Fuse.............................................................................................................. 15 A / 7.5 A
120 VAC / 240 VAC
Nominal .................................................................................100 / 240 VAC, 50 / 60 Hz
Minimum ............................................................................................................. 90 VAC
Maximum .......................................................................................................... 264 VAC
Installation
The refrigerator should be located and secured on a solid surface with no gap
between the bottom rails of the refrigerator and the supporting surface.
AC supply
Battery
*Recommended source:
Sure Power Industries, Inc.
1-800-845-6269
www.Surepower.com
6
Circuit
Art02373