EXTERNAL TEMPERATURE CHANGE
The thermostat can be controlled by an external temperature change signal. In that case the tem-
perature setting value can be changed into a predetermined value with an external signal.
˚
C
This function enables a centralized temperature reduction in order to save in energy consump-
tion e.g. during a stay away from home for a longer time. The default for temperature reduction
is +16 °C and its value can be changed in the thermostat settings.
NOTE! During the temperature change mode the only values that can be changed are day and
time.

OTHER FUNCTIONS

TEMPORARY BYPASSING OF THE WEEKCLOCK
In the weekclock mode the temperature setting value can temporary be changed manually with
the arrow buttons. The change is valid until the beginning of the following period after which
the weekclock will continue according to the earlier determined program.
BUTTON LOCK
The buttons can be locked and unlocked by pushing the both arrow buttons simultaneously for
a long time. When the buttons are locked the symbol of the button lock is displayed.
FAULT SIGNALS
If the room temperature sensor is faulty the code"E1" is displayed.
If the fl oor temperature sensor is faulty the code"E2" is displayed.
THE EMERGENCY OPERATION TIME
If the power is switched off for less than 2 hours all the settings will remain. If the power cut
lasts longer than 2 hours the clock will reset. After the power is switched on the right time
must be entered so that the thermostat is able to follow the timed settings.
SETTINGS
MOVING IN THE SETTING MENU
The thermostat settings can be changed in the setting menu. The thermostat can be changed
from the basic mode into the setting mode by pushing the OK button for a longer time and
return to the basic mode by pushing the OK button once again for a longer time.