Laars MIGHTY THERM2 MT2H Instructions D'installation Et D'utilisation page 28

Masquer les pouces Voir aussi pour MIGHTY THERM2 MT2H:
Table des Matières

Publicité

Page 24
INTER-
RUPTEUR
PRINCI-
PAL
CAVALIER
POMPE
POMPE
ENTRÉE ÉTAGE
ÉTAGE
ENTRÉE ÉTAGE
ÉTAGE
LIMITEUR DE
CONDUIT
LIMITE HAUTE
PRESS
PRESS
TEMPÉRATURE
OBSTRUÉ
GAZ BAS
GAZ HAUT
MAX. AUTO EN
OPTION
MANUELLE
INTERVER-
ROUILLAGE
SITE
CONTRÔLE
CONTACTEUR
VENTILATEUR
SÉLECTEUR
POMPE
ARRÊT ALARME
PÔLE
Figure 17.
Schéma de câblage – modèle 1000
120 V CA
SOUFFLANTE 1
HAUTE
BASSE
120 V CA
24 V CA
INTER. BIPOLAIRE
TERRE
BIDIRECTIONNEL
LOCAL/DISTANT
ÉTAGE
ÉTAGE
RÉINITIA-
ÉTAGE
LISATION
VANNE DE
GAZ
ÉTAGE
ÉTAGE
DE DÉBIT
Gaz
TÉMOIN
VANNE DE GAZ
ÉTAGE
Gaz
INIT
RELAIS, À RETARD
ALARME SONORE
TÉMOIN
CONTACT SEC
D'ALARME
BORNIER
PÔLE
TB1-1
TB1-1
INTER-
MAIN
MAIN
RUPTEUR
POWER
POWER
SWITCH
SWITCH
PRINCIPAL
DPDT
DPDT
IGN
IGN
BD #1
BD #1
35 67
35 67
L1
L1
IGN
BD #2
35 67
35 67
L1
K3
K3
VERS
2
2
1
1
POMPE
1
1
IGN
IGN
BD #1
BD #1
35 67
35 67
F1
F1
35 67
35 67
F1
F1
IGN
IGN
BD #2
BD #2
PRESS
GAZ BAS
GAZ HAUT
LOW
HIGH
GAS
GAS
INTERVER-
Field
Field
ROUILLAGE
Interlock
Interlock
SITE
3
3
4
4
SÉLECTEUR
PUMP
PUMP
SELECT
SELECT
POMPE
SWITCH
SWITCH
IGN
BD #1
35 67
L.O.(G)
IGN BD #2
35 67
L.O.(G)
Figure 18.
LAARS Heating Systems
L1
L1
N1
N1
120 V CA
120 VAC
120 VAC
CAVALIER
JUMPER
JUMPER
HSI #1
HSI #1
IGN
IGN
IGN
IGN
BD #1
BD #1
BD #1
35 67
35 67
35 67
35 67
S1
S1
S2
S2
HSI #2
HSI #2
IGN
IGN
IGN
IGN
BD #2
BD #2
BD #2
35 67
35 67
35 67
35 67
S1
S1
S2
S2
HAUTE
HIGH
K1
K1
K1
K1
HAUTE
HIGH
HIGH
K2
K2
K2
K2
BASSE
LOW
LOW
POMPE
PUMP
PUMP
120 V CA
120 VAC
120 VAC
P1
P1
P2
P2
24 V CA
24 VAC
24 VAC
IGN
IGN
IGN
IGN
BD #1
BD #1
BD #1
BD #1
35 67
35 67
35 67
35 67
24V
24V
TERRE
GND
GND
35 67
35 67
35 67
35 67
TERRE
IGN
IGN
24V
24V
GND
GND
IGN
IGN
IGN
IGN
BD #2
BD #2
BD #2
BD #2
BD #1
BD #1
35 67
35 67
K1
F2
F2
35 67
35 67
K2
F2
F2
IGN
IGN
BD #2
BD #2
ENTRÉE ÉTAGE 1
INPUT STAGE 1
ÉTAGE 1
STAGE 1
ENTRÉE ÉTAGE 2
INPUT STAGE 2
STAGE 2
ÉTAGE 2
LIMITEUR DE
CONDUIT
LIMITE HAUTE
MANUAL
PRESS
AUTO RESET
TEMPÉRATURE
OBSTRUÉ
RÉINITIA-
RESET
ÉTAGE
BLOCK
STAGE 1
HIGH LIMIT
MAX. AUTO EN
LISATION
HIGH LIMIT
OPTIONAL
OPTION
FLUE
MANUELLE
2
STAGE 2
ÉTAGE
CONTACTEUR
Proof
of Fan
Press
Press
DE DÉBIT
#1
35 67
35 67
CONTRÔLE
6
6
FLOW
VENTILATEUR
SWITCH
IGN
IGN
BD #1
BD #1
5
CONTACTEUR
Proof
Proof
DE DÉBIT
Press
Press
of Fan
of Fan
#2
#2
35 67
35 67
IGN
IGN
INIT
BD #2
BD #2
Initiate
Initiate
K3
RELAIS, À RETARD
Relay
Relay
Delay on Break
Delay on Break
ALARME
ARRÊT
ALARM
ALARM
SONORE
ALARME
BELL
BELL
SILENCE
SILENCE
IGN
BD #1
35 67
L.O.
IGN BD #2
35 67
R
L.O.
CONTACT SEC
ALARM
ALARM
D'ALARME
DRY CONTACT
DRY CONTACT
BORNIER 1
TERMINAL
TERMINAL
BLOCK 1
BLOCK 1
PÔLE
PÔLE
POLE 5
POLE 5
POLE 6
POLE 6
Schémas de câblage – modèles 1250 à 2000
IGN
IGN
BD #1
BD #1
35 67
35 67
L2
L2
IGN
IGN
BD #2
BD #2
35 67
35 67
L2
L2
SOUFFLANTE 1
BLOWER 1
BLOWER 1
HIGH
BASSE
LOW
LOW
SOUFFLANTE 2
BLOWER 2
BLOWER 2
VERS
TO
TO
POMPE
PUMP
PUMP
10
STAGE 1
STAGE 2
INTER. BIPOLAIRE
BIDIRECTIONNEL
LOCAL/REMOTE
LOCAL/DISTANT
DPDT SWITCH
T'stat
T'stat
STAGE 1
35 67
35 67
STAGE 2
35 67
35 67
8
T'stat
T'stat
VANNE DE
Gas Valve
Gas Valve
GAZ
stage 1
stage 1
ÉTAGE
Gaz
Gas
Gas
7
TÉMOIN
35 67
35 67
LIGHT
LIGHT
IGN
IGN
BD #1
BD #1
VANNE DE GAZ
Gas Valve
Gas Valve
Gaz
Gas
Gas
ÉTAGE
stage 2
stage 2
35 67
35 67
9
9
IGN
IGN
BD #2
BD #2
TÉMOIN
LIGHT
H2329000D

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mighty therm2 mt2vMighty therm2 mt2h 500Mighty therm2 mt2h 750Mighty therm2 mt2h 1000Mighty therm2 mt2h 1250Mighty therm2 mt2h 1500 ... Afficher tout

Table des Matières