Réf. Erreur Niveau Texte D'information - Leister SEAMTEK 900 AT Notice D'utilisation

Table des Matières

Publicité

Réf. erreur Niveau Texte d'information
2
232
240
2
241
2
242
2
250
2
251
2
252
2
258
2
259
2
260
2
261
2
262
2
263
2
264
2
265
2
266
2
267
2
268
2
269
2
270
2
38
Error 232: Close File in Write Machine Settings
Error 240: Open File in Read Recipes
Error 241: Read CSV Line in Read Recipes
Error 242: Close File in Read Recipes
Error 250: Open File in Write Recipes
Error 251: Write CSV Line in Write Recipes
Error 252: Close File in Write Recipes
Error 258: Can not open Backup Source File.
Error 259: Can not open Backup Destination File.
Error 260: Can not read Backup Source File.
Error 261: Can not write Backup Destination File.
Error 262: Can not close Backup Destination
File.
Error 263: Can not close Backup Source File.
Error 264: Can not open Recovery Source File.
Error 265: Can not open Recovery Destination
File.
Error 266: Can not read Recovery Source File.
Error 267: Can not write Recovery
Destination File.
Error 268: Can not close Recovery
Destination File.
Error 269: Can not close Recovery Source File.
Error 270: Air Temperature Setpoint not reached.
Lower Airvolume or Temperature Setpoint, restart
Heater
Description
In SettingsWrite(), Error Closing File
In RecipesRead(), Error Recipes Open File
In RecipesRead (), Error Read CSV Line Recipes
In RecipesRead (), Error Closing File
In RecipesWrite()
Error Machine Settings Open File
In RecipesWrite (), Error Write CSV Line Machine
Settings
In RecipesWrite (), Error Closing File
Machine Settings File on PLC corrupted. Do
recover your Data from your Memory Stick.
Missing Memory Stick.
Machine Settings File on PLC corrupted. Do
recover your Data from your Memory.
Missing Memory Stick.
Missing Memory Stick.
Machine Settings File on PLC corrupted. Do
recover your Data from your Memory.
Machine Settings File on Memory Stick corrup-
ted. Do backup your Data from PLC to Memory
Stick.
Machine Settings File on PLC corrupted.
Machine Settings File on Memory Stick corrup-
ted. Do backup your Data from PLC to Memory
Stick.
Machine Settings File on PLC corrupted.
Machine Settings File on PLC corrupted.
Machine Settings File on Memory Stick corrup-
ted. Do backup your Data from PLC to Memory
Stick.
Air Temperature during Heat-Up (slow Controller)
can not be reached. Setpoint is too high, Air
Volume is too high. Ambient Temperature or Inlet
Air Temperatur of SEAMTEK AT is too low.