USING YOUR HUMIDIFIER – HEV620
HEV620 Digital Display
Key
A. Power
B. Moisture Output
E
C. Humidity Control
D. Timer
D
E. Check Filter
F. Refill
Power
1. Plug humidifier into a 120V outlet.
CAUTION:
To avoid electric shock, DO NOT plug humidifier into outlet with wet hands.
2. Press Power Button
(A).
Humidifier will turn on to high output and high humidity settings. Press again to turn off.
If humidifier was programmed before turning off, previous settings will be remembered.
Unplugging the humidifier resets to default settings.
Moisture Output
3. Press the Moisture Output button
moisture output settings.
A higher setting will provide more moisture output. The fan will pull more moisture off the
Wicking Filter and into the air. The water level in the Water Tank will decrease faster with a
higher setting, since more moisture is going into the air.
A lower setting will provide less moisture output. The fan will run quieter, and the Water Tank
will not have to be filled as frequently, since less moisture is going into the air.
NOTE: While the humidifier is operating, you will hear the fan running but will not see the
moisture output. This is normal for an evaporative humidifier.
Humidity Control
4. Press the Humidity Control arrows
To scroll through the numbers faster, press and hold the arrow for 3 seconds.
Release the button once the desired level is shown. Display will blink three times showing
the SET humidity level, then the display will return to show the current room humidity level.
CURRENT will illuminate on the display to indicate the curent room humidity level.
Symbols
B. Moisture
Output
F
D. Timer
C
E. Check
B
Filter
A
F. Refill
(B) to toggle through low, medium, and high
(C) to set the desired humidity level.
6
USING YOUR HUMIDIFIER – HEV620
The humidistat can be set between 30%-69%. Below 30%, LO will illuminate on the display
to indicate the minimum humidity level. Above 69%, the display will show HI to indicate the
maximum humidity level is set.
NOTE: The % number displayed on the control panel represents the relative humidity
(Canada only)
(RH) as measured at the Humidistat sensor. The relative humidity in your room may
vary from the number displayed on the humidifier. To measure the RH level in your
room, consider using a Honeywell humidity monitor (HHM10 or H10C) that can be
moved around in the room.
Humidity Reached
When the set humidity level is reached HUMIDITY REACHED will appear on the display
and the humidifier will turn off. As long as HUMIDITY REACHED is illuminated,
the fan will not run.
Once the humidity level drops below the set level, HUMIDITY REACHED will disappear
and the humidifier will start running again.
To increase the set humidity level, press the Humidity Control arrows
Timer
Press the
NOTE: Humidifier will continue to cycle on and off to maintain the set humidity level while
the Timer is set. At the end of the timed cycle, the humidifier will power off, regardless of the
humidity setting. Any time the humidifier is manually turned off (with the power button or by
unplugging) the timer will reset to OFF setting.
(CONTINUED)
(US models only)
button (D) to set the Timer to 4, 8 or 12 Hours.
7
.