Whale Orca Auto 1300 Manuel D'installation Et D'utilisation page 4

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
9.iv Electrical Wiring
Ensure all wire connections are at the highest level above water. Use marine grade
wire connectors only and 16 AWG tinned copper wire. Waterproof all connections
with suitable materials (see figure 3).
Connect positive (+) brown
and white stripe wire to the
automatic side of the switch.
Connect negative (-) black
wire to ground.
Connect yellow crimp to
manual side of switch. DO
NOT disconnect the brown
and white solid wires from the
yellow crimp.
Install a fuse holder within 72"
(183cm) of the positive (+)
battery terminal.
To test system, feed water into
the pump. If flow rate appears
low, ensure wires are connected properly:
Brown and white stripe to positive
NOTE - Reversed wiring reduces performance and can cause pump failure.
If you are not familiar with applicable electrical standards, ensure that the unit is installed by
a qualified electrician/ technician.
WARNING: Fire hazard. Wiring must comply with applicable electrical standards and include a
properly rated fuse or circuit breaker. Improper wiring can cause a fire resulting in injury or death.
NOTE Switch off the power prior to making connections. Suggested wiring information is given as a
guide only. For full information, refer to the USCG, ABYC and ISO regulations for marine
applications and wiring gauges, connectors and fuse protection.
9.v FITTING THE FUSE
Fuse rating for BE1482 (12V d.c.) pumps - 7 Amp automotive.
Fuse rating for BE1484 (24V d.c.) pumps - 5 Amp automotive
An in-line fuse assembly must be fitted to the positive side of the pump.
PURPOSE OF FUSE: The purpose of this fuse is to protect the pump from serious damage in the
event of system blockages, therefore please ensure all valves are fully open before operating the
pump.
If the fuse blows:
a) Check that all system valves/stop cocks are open
b) Check that the inlet and outlet ports are not blocked
c) Check that the rest of the system is not blocked
d) Check for reverse polarity connection
10. MAINTENANCE
This Whale Orca Auto 1300 is designed to only require minimal maintenance.
Annual Checks
Whale advise that the boat's plumbing system is checked at least annually for leaks and
obstructions. Also an electrics check including testing the pump is advisable.
Optimal Performance
Ensure this product is clear of debris
WARNING: Do not use abrasive cleaners.
4
Manual
Switch
Fuse
Automatic
Battery
Figure 3 - Wiring
Brown and White solid wires
connected by yellow crimp
Off
Brown and white
stripe wire
Black wire
Orca Auto
Black to negative (battery)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Be1482Be1482bBe1484Be1484b