Table Des Matières; What To Do If You Smell Gas - DeWalt DXH135HD Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING: RISK OF FIRE OR EXPLOSION
• Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS?

• Open windows.
• DO NOT try to light any appliance.
• DO NOT operate any electrical switches.
• DO NOT use any telephone in building. Immediately call the
local gas supplier from an outside telephone. Follow the gas
supplier's instructions.
• DO NOT touch any electrical switch; do not use any phone in your
building.
• If you cannot reach your gas supplier, call the Fire Department.
Specifications
MODEL
:
BURN RATE:
FUEL RATE:
ELECTRICAL INPUT:
LINE PROTECTION:
MIN. OPERATING VOLTAGE:
PRESSURE SETTING:
MAX. OUTLET TEMPERATURE:
FUEL TANK CAPACITY
IGNITION:
SPARK GENERATOR:
PRIMARY SAFETY CONTROL:
CERTIFICATION:
DXH135HD
35,000 Btu/hr (39.5 kw)
1.0 gal /HR (3.8 L / HR)
115V, 60Hz, 5.5A
20 AMPS
110V
6.8 PSI (47 kPA)
1450 °F (787°C)
14 gal (53 L)
Direct Spark, Continuous
Igniter, 13 kV, 10mA
Solid State Control
CSA
U
C
CONTENTS
WARNINGS ......................................................................... 2-3
HEATER SPECIFICATIONS ..................................................... 3
OPERATING PRECAUTIONS .................................................. 4
SAFETY PRECAUTIONS......................................................... 4
OPERATING INSTRUCTIONS .............................................. 4-5
MAINTENANCE, STORAGE AND SERVICE ........................ 5-7
WIRING DIAGRAM ................................................................. 7
TROUBLE SHOOTING............................................................ 8
PARTS LISTS/EXPLODED VIEWS...................................... 9-11
WARRANTY ......................................................................... 12
INSTRUCTIONS FOR ORDERING PARTS ............................ 12
CAUTION: CSA certified for use with only No. 1-K kerosene fuel. Factory Tested:
No.2-K kerosene, No.1 or No.2 Diesel, No.1 or No.2 fuel oil or JP8 Jet A fuel
DXH190HD
190,000 Btu/hr (55.6 kw)
1.4 gal/hr (5.3 L /HR)
115V, 60Hz, 5.5A
20 AMPS
110V
7.5 PSI (51.7 kPA)
1450 °F (787°C)
14 gal (53 L)
Direct Spark, Continuous
Igniter, 13 kV, 10mA
Solid State Control
CSA
U
C
3
DXH215HD
215,000 Btu/hr (62.9 kw)
1.61 gal/hr (6.1 L /HR)
115V, 60Hz, 5.5A
20 AMPS
110V
8.4 PSI ( 57.9 kPA)
1450 °F (787°C)
14 gal (53 L)
Direct Spark, Continuous
Igniter, 13 kV, 10mA
Solid State Control
CSA
U
C

Publicité