Make sure the floor is level, in this way preventing any vibration or noise.
Make sure that the appliance has correct ventilation. Do not block the ventilation grid of the
condensing unit.
3.6 CONNECTIONS
Once the device has been fitted into the hole of the furniture destined for this purpose, the
anchoring is carried out by means of the anchoring system supplied as shown in the Figure 3.
The condensing unit should be well ventilated for an optimum performance of
the cooling system. Please follow Figure 7 for designing the furniture's
ventilation grill.
The control box located on the lower part of the appliance can easily be moved to the side of
the technical cabinet if required (for example in the case of having the front access of the
appliance closed due construction reasons) as described in figure 5.
At the same time, it can be removed from the device and installed in any other panel (for
example, in the front of buffet to operate and regulate the appliance without need to open the
door). In Figure 9, you can find the hole position to install the thermostat in the front panel of a
furniture. The control panel can be moved a maximum of 1.6m from the original position.
In figures 4 it is explained how to move out the device from the furniture if maintenance or
repair is required.
REMOTE UNIT OPTIONAL
All refrigerated inlet is supplied in copper pipes, both for connecting the high pressure (liquid)
and low pressure (gas) lines of the refrigeration unit are sized 3/8". It is not included the
thermostatic expansion valve, capillary tube, solenoid valve nor the cutoff valve.
The electrical connection socket for solenoid valve or refrigeration unit is provided by
connection terminals, located in the junction box for a maximum compressor power of 1 1/2 ".
For higher powers, it is necessary to implement a relay or contactor, this element will not be
supplied.
4 OPERATION
4.1 GENERAL INFORMATION
The regulation is carried out by means of a digital electronic thermostat, allowing adjusting the
different temperatures of the appliance depending on the existing environmental conditions.
Machine maintenance operations must only be carried out by specialized Technicians provided
with suitable personal protection equipment. See figure 8 for the thermostat information.
4.2 CONTROL PANEL DESCRIPTION
1- Display
2- Main On-Off buttom (except light)
3- Set
4- ECO function
5- Light On-Off
6- Programing and disconnect sound/ alarm
7- Up ▲
8- Down ▼, manual defrosting (only in refrigeration)