Motor Connection - Cardin RPQ Mode D'emploi

Radioprogrammateur pour volets roulants et rideaux de garage
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Motor connection

• Connect one of the motor phases to binding post 3 - F1; the neutral wire to binding post
4 - C; and the second motor phase to binding post 5 - F2.
• Connect the 230V power supply to binding posts 1 and 2.
• If the motor rotates in the wrong direction, invert the F1 and F2 phase wires.
Selector switch connection
• Wire a selector switch or an open close button between binding posts 7 - 8
- 9 and select the required function using dip-switch D1 as follows:
Function selection dip-switches for binding posts 7, 8 and 9
dip 1
dip 2
OFF
OFF
ON
OFF Sequential button
OFF
ON
ON
ON
T1
T2
Open
Close
Timer
Open
Close
Open
Close
Default option
Sequential button = open - stop - close - stop
Dead man function only during closing
Dead man function during opening and closing
15