10.5.1 Connection to a standard socket
» Plug the appliance into a standard socket.
10.5.2 Permanent connection to an appliance
junction box
WARNING Electrocution
In the case of a permanent connection, the appliance
must be able to be separated from the power supply
by an isolator that disconnects all poles with at least
3 mm contact separation.
Material losses
◦ Trim the power cable so it leads directly to the
appliance connection socket.
◦ Ensure that, after trimming the power cable,
the appliance can still be removed from the wall
without a problem.
» Trim the power cable by cutting off the plug.
» Connect the power cable to a suitable appliance
junction box.

11. Commissioning

The appliance is ready for operation as soon as it has
been fixed to the installation wall and connected to the
mains.
» Remove the protective film from the programming
unit.

12. Troubleshooting

The power cable must only be replaced (for example if
damaged) by a qualified contractor authorised by the
manufacturer, using an original spare part.

13. Appliance handover

Explain the functions of the appliance to the user. Draw
special attention to the safety instructions. Hand over the
operating and installation instructions to the user.

14. Specification

14.1 Dimensions and connections

345
i13
Wall mounting bracket
126
179
i13
SH 2020

14.2 Energy consumption data

The product data complies with EU regulations relating to
the Directive on the ecodesign of energy related products
(ErP).
Product information on electric individual room heaters to
regulation (EU) 2015/1188
Manufacturer
Heating output
Rated heating output P
nom
Minimum heating output (standard value) P
Maximum continuous heating output P
Auxiliary power consumption
At rated heating output el
max
At minimum heating output el
min
In standby el
SB
Type of heating output/room temperature control
Single stage heating output, no room temperature
control
Two or more manually selectable stages, no room
temperature control
Room temperature control with mechanical thermostat
With electronic room temperature control
Electronic room temperature control and time of day
control
Electronic room temperature control and day of week
control
Other control options
Room temperature control with motion detection
Room temperature control with window open detec-
tion
With remote control option
With adaptive control of heating start
With operating time limitation
With black bulb sensor

14.3 Data table

Electrical data
Connected load
Power supply
Rated current
Frequency
Energy data
Room heating seasonal efficiency η
Dimensions
Height
Width
Depth
Weights
Weight
Versions
Version
Frost protection setting
IP rating
Protection class
Colour
Values
Output stages
Setting range
Operating noise
Installation
SH 2020
60239532
Star Unity
kW
kW
min
kW
max,c
kW
0.000
kW
0.000
kW
0.000
SH 2020
60239532
W
2000
1/N/PE ~ 230 V
A
Hz
%
s
mm
mm
mm
kg
Wall mounted device
°C
IP 24
Alpine white
°C
5 - 30
dB(A)
AG
2.0
0.0
2.0
-
-
-
-
-
x
-
x
-
x
-
-
8.7
50/-
39
470
345
126
5.3
7
I
2
48
43

Publicité