Configuration Menu; Actual Values; Time Programs - Elcalor SH 2020 Utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Display
Description
Switch "Window open detection" function on and off
Select time program (Pro1, Pro2, Pro3, Pro4) or deac-
tivate (off)
Switch "Adaptive start" function on and off
Set silent mode
Lo = quiet 1000 W base heating stage
Hi = powerful 2000 W rapid heating stage
To change the setting of a menu item, call the relevant
menu item up using "+" and "–". Press "OK".
As soon as the "Editable parameter" symbol appears, you
can change the setting of the menu item with "+" and "–".
Press "OK" to save the setting.
To exit the standard menu, press "Menu". The standard
display appears.
5.3.1 120-minute short-time timer
With the 120-minute short-time timer, you can activate
comfort mode for a selected time of up to 120 minutes.
During this selected time, the appliance heats to the set
comfort temperature. After this, the appliance operates
in setback mode.
If you wish to use the 120-minute short-time timer, select
time program Pro4 from the standard menu.
The standard display shows the selected time in minutes
as well as the "Editable parameter" symbol. Using the "+"
and "-" buttons, you can select any length of time from
10 - 120 minutes.
To activate the short-time timer, press "OK". The appli-
ance switches to comfort mode until the end of the se-
lected time. The minute display flashes during this period.
If you wish to stop the short-time timer, press and hold
"OK" for longer than 3 seconds.
At the end of the selected time, the appliance automati-
cally reverts to setback mode.
5.3.2 Silent mode
You can choose between the following two heating out-
puts with matched fan speed:
Base heating stage
Set "Lo" in the standard menu for silent mode. The appli-
ance heats with a heating output of 1000 W and reduced
fan speed. The LED on the programming unit illuminates
green.
Note
Do not operate the appliance at the base heating
stage if the room where it is installed has cooled
down significantly.
» If the room has cooled down significantly,
switch the appliance to the rapid heating stage
in order to ensure normal appliance operation.
Rapid heating stage
Set "Hi" in the standard menu for silent mode. The ap-
pliance heats with a heating output of 2000 W and fast
fan speed.
Select the powerful rapid heating stage if you need to heat
up a cold room rapidly to the selected temperature. Then
set the base heating stage again.
When the selected room temperature has been reached,
it is maintained by the appliance through periodic heating.

5.4 Configuration menu

Display
Description
I1-I2

Actual values

Pro1-Pro3 Time programs
P1-P5
Parameter
In the configuration menu, you can call up actual values,
set time programs and adjust parameters.
To access the configuration menu, press and hold "Menu".
After approx. 3 seconds, actual value I1 is displayed.
Use "+" and "–" to switch between the individual actual
values, time programs and parameters.
To exit the configuration menu, press "Menu". The stand-
ard display appears.
5.4.1 Actual values
The following actual values can be called up:
Display
Description
I1
Actual room temperature
I2
Relative heating time
(The counter can be reset via parameter P5.)
Note
The counter for relative heating time (I2) counts in
complete hours how long the appliance heats for.
When the appliance is switched off, any heating
phase of less than 60 minutes is not recorded.

5.4.2 Time programs

Three time programs are available. Time programs Pro1
and Pro2 are pre-configured at the factory. Time program
Pro3 can be set according to your individual requirements.
Display
Description
Pro1
Time program "Daily"
- Repeated: Monday to Sunday
Pro2
Time program "Weekdays"
- Repeated: Monday to Friday
Pro3
Time program "User defined"
- up to 14 comfort phases, freely configurable
Note
To use a time program, select the required time
program from the standard menu (see chapter "Set-
tings / Standard menu").
Note
Ensure the day of the week and the time are set cor-
rectly when setting the time programs.
Note
The following applies to all time programs (Pro1,
Pro2, Pro3):
If the end time is later than 23:59 h, the end time will
automatically be moved to the next day of the week.
The comfort phase is maintained past midnight and
will end on the next day at the set end time.
Operation
Unit
[°C] | [°F]
[h]