7. Troubleshooting

Problem
Cause
Room does not get
Temperature set too
warm enough. Ap-
low on the appliance.
pliance does not
get hot.
No power supply.
Room does not
Overheating. High
get warm enough
limit safety cut-out lim-
although the appli-
its heating output.
ance is hot.
Heat demand of the
room is higher than
the appliance output.
The room gets too
Appliance tempera-
hot.
ture is set too high.
Window open
Appliance does not
detection does not
detect a pronounced
respond.
temperature drop
when venting. (Win-
dow open detection
requires a previously
stable room temper-
ature.)
Window open detec-
tion is not enabled.
"Adaptive start"
This function is only
function does not
effective with a time
work as required.
program activated.
Severely fluctuating
room temperature or
the appliance learning
procedure has not
been completed.
"Adaptive start" func-
tion is not enabled.
"Err" or "E..." is
Internal fault detected. Notify the qualified con-
displayed.
If you cannot remedy the fault, contact your qualified con-
tractor. To facilitate and speed up your request, provide
the number from the type plate (000000-0000-000000).
Remedy
Check the temperature
set on the appliance. Ad-
just if necessary.
Check position of the ON/
OFF switch, RCD and
fuse/MCB in your fuse
box.
Eliminate the cause (dirt
or obstructions at the
air intake or discharge).
Observe minimum clear-
ances.
Remedy heat losses
(Close windows and
doors. Avoid constant
venting.)
Check the selected room
temperature. Adjust if
necessary.
Wait a while after making
settings on the appliance,
until the room tempera-
ture has fully stabilised.
Avoid obstructions to air
changes between appli-
ance and indoor air.
Manually switch the appli-
ance to standby mode for
the duration of venting.
Switch on window open
detection in the standard
menu.
Use the time programs
for optimised heating con-
venience.
Wait a few days for the
behaviour to stabilise.
Switch on the "Adaptive
start" function in the
standard menu.
tractor.

INSTALLATION

8. Safety

Only a qualified contractor should carry out installation,
commissioning, maintenance and repair of the appliance.
8.1
General safety instructions
We guarantee trouble-free function and operational relia-
bility only if original accessories and spare parts intended
for the appliance are used.
WARNING Electrocution
When installing the heating appliance in rooms with
a bath or shower, observe the safety zone according
to VDE 0100, section 701 [or local regulations], in
accordance with the details on the appliance type
plate.
CAUTION Burns
◦ Only mount the appliance on a vertical wall that
is temperature-resistant to at least 85 °C.
◦ Maintain the minimum clearances to adjacent
objects.
Material losses
◦ If connecting the appliance via a socket, ensure
that this is easily accessible once the appliance
has been installed.
◦ Never install the appliance directly below a wall
socket.
◦ Ensure that the power cable is not in contact
with any appliance components.
8.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regula-
tions and instructions.

9. Appliance description

9.1
Standard delivery
The following are delivered with the appliance:
◦ Wall mounting bracket (hooked into the appliance)
10. Installation

10.1 Minimum clearances

≥100
≥100
Operation - Installation
≥500
41